• • • POWER • • •


POWERING THE NEXT


GENERATION OF DATA CENTRES: WHY M&E ENGINEERING MUST EVOLVE TOGETHER


Power density is redefining the design brief


BY GARY MCGILLAN, ENGINEERING DIRECTOR, TES POWER


he AI boom is placing demands on data centre infrastructure that established design approaches were never built to handle. Goldman Sachs Research forecasts that power demand from data centres will rise by 50 per cent by 2027 compared with 2023, and by as much as 165 per cent by the end of the decade. Much of that growth is concentrated in high-density AI environments, where rack densities already sit between 40kW and 130kW and future chips are projected to reach 250kW per rack. As AI workloads push rack densities to unprecedented levels, the traditional separation between electrical and mechanical design is becoming increasingly difficult to maintain. Every kilowatt delivered to the rack ultimately becomes heat that must be removed, meaning decisions around electrical infrastructure, cooling architecture and resilience strategies are now intrinsically linked. For developers seeking to future-proof facilities, M&E coordination is no longer a best practice. It is becoming a design necessity.


T


The capacity of the power path determines how much IT load a facility can support, and every watt delivered to the rack becomes heat that mechanical systems must remove. In high-density AI halls, decisions around electrical capacity directly influence cooling plant sizing, white-space layouts and available service corridors. Power and cooling can no longer be designed in isolation because changes to one system often create consequences for the other. Liquid cooling adds a further electrical dimension, since the pumps and coolant distribution units serving high- density halls are critical loads that must sit within the resilient power path and influence UPS sizing. AI workloads also place new stresses on the power chain itself. Unlike conventional computing environments, large GPU clusters can move from near-idle to peak demand within seconds before falling away just as rapidly. This creates cyclical thermal stresses throughout the electrical infrastructure, with copper conductors and connections repeatedly expanding and contracting as loads fluctuate.


At the same time, switchgear frequently operates within higher ambient temperature environments as cooling strategies focus on maximising IT performance. This makes collaboration between mechanical and electrical


14 ELECTRICAL ENGINEERING • NOVEMBER 2026


disciplines increasingly important to ensure electrical equipment remains within its operating envelope throughout the facility lifecycle.


Engineering for reliability


under pressure Reliability remains the defining requirement of data centre infrastructure, and any interruption can have significant consequences for operators and their customers. For electrical manufacturers, the challenge is no longer simply delivering capacity. Infrastructure must also accommodate fluctuating AI loads, integrate with evolving cooling technologies and support increasingly compressed construction programmes.


The way these systems interact with mechanical


services and building layouts is equally important, and early engagement between engineering teams helps identify design conflicts before they reach the site. Building Information Modelling (BIM) supports this by allowing teams to understand how systems fit together ahead of construction.


The growing role of


modular construction Developers also face considerable pressure to deliver new capacity quickly, with major AI operators expecting some hyperscale builds to complete in just 14 to 15 months. Modular


electricalengineeringmagazine.co.uk


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36