search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
RCD's Double Pole Type A 30mA


• Bidirectional • BS7671 • Two module • 30mA • 6kA • Positive contact status indicator • Device capable of being locked in 'off' position using a device lock


Product Code Description CUR4030A CUR6330A CUR8030A CUR10030A


Compact RCD Bidirectional Compact RCD Bidirectional Compact RCD Bidirectional Compact RCD Bidirectional


TYPE A BIDIRECTIONAL


Rating 40A 63A 80A


100A


Modules 2 2 2 2


Double Pole Type A 100mA


• Bidirectional • BS7671 • Two module • 100mA • 6kA • Positive contact status indicator • Device capable of being locked in 'off' position using a device lock


Product Code Description CUR100100A


Compact RCD Bidirectional CUR100100TDA Compact RCD Bidirectional, time delayed TYPE A BIDIRECTIONAL


Rating 100A 100A


Modules 2 2


Double Pole Type B 30mA


• Bidirectional • BS7671 • Two module • 30mA • 6kA • Positive contact status indicator • Device capable of being locked in 'off' position using a device lock


TYPE B


Product Code Description CUR6330BN


Compact RCD Bidirectional


Rating 63A


BIDIRECTIONAL


Modules 2


Double Pole Type B+HP 30mA


• Bidirectional • BS7671 • 2 module • 6kA • Minimum trip threshold: 150mA for high – frequency current >1kHz • Detection capability: 20kHz for high-frequency currents • Positive contact status indicator • Device capable of being locked in 'off' position using a device lock


TYPE B+HP


Product Code Description CUR6330BHP


Compact RCD For Heat Pumps CUR10030BHP Compact RCD For Heat Pumps 20 kHz BIDIRECTIONAL


Rating 63A


100A


Modules 2 2


RCD Types


Type A: Ensures tripping for residual AC currents and pulsating DC currents. Where loads produce DC currents such as electric vehicle chargers and washing machines, and where current has the ability to flow in two directions through the device.


Type B: Ensures tripping for residual AC currents, pulsating DC and smooth residual DC currents, suitable for PV application, inverters and Electric vehicle charging equipment with smooth DC greater than 6mA, and where current has the ability to flow in two directions through the device.


Type B+HP: Providing tripping for residual AC currents, pulsating DC, smooth residual DC currents, and high frequency DC currents. Developed specifically for Heat Pump applications. Incorporating inbuilt surge to handle initial inverter startups preventing nuisance tripping. 150mA minimum tripping threshold for frequencies greater than 1kHz. Bidirectional, Double Pole.


26


BG Circuit Protection


BG Circuit Protection


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32