Dual RCD Consumer Units – Populated
Allows the installer to split the consumers power needs across two 30mA Type A RCD’s, for example lighting and sockets circuits.
• Supplied complete with MCBs fitted, see table • Available with type 2 SPD • Dual RCD Units supplied with Hi-integrity as standard designed to provide maximum flexibility for protected and unprotected circuits
• Each consumer unit supplied with spare cover blanks • Lockable covers also available, see accessories section
Qty of supplied Devices
4 5 6 8 9
10
MCB Device Breakdown
1 x 6A, 1 x 16A, 1 x 32A, 1 x 40A 1 x 6A, 1 x 16A, 2 x 32A, 1 x 40A
2 x 6A, 1 x 16A, 2 x 32A, 1 x 40A 3 x 6A, 1 x 16A, 3 x 32A, 1 x 40A 3 x 6A, 2 x 16A, 3 x 32A, 1 x 40A 3 x 6A, 2 x 16A, 4 x 32A, 1 x 40A
B-Curve Y
Y Y Y Y Y
Bidirectional Y
Y Y Y Y Y
Product Code
Modules Ways
16 19
22
16 19
22
10 13
16 9
Main Switch
Populated Main Switch, 100A Type A RCD + 100A Type A RCD CF16D11P10 CF19D11P13 CF22D11P16
100A 100A 100A
12 15
100A 100A 100A
RCD
2 x 100A 2 x 100A 2 x 100A
Populated Main Switch, 100A Type A RCD + 100A Type A RCD + Surge Protection Device CF16D11PS9 CF19D11PS12 CF22D11PS15
2 x 100A 2 x 100A 2 x 100A
MCB's
10 10 12
8
10 12
SPD Type 2
- - -
Y Y Y
IP
IP20 IP20 IP20
IP20 IP20 IP20
Cover Blanks
2 4 4
2 4 4
RCD Incomer
A RCD Incomer allows the protection of isolating both poles of the incoming supply with the protection of a 30mA Type A RCD, a great way to add an additional board in workshops, garages, garden offices and sheds.
• RCD consumer unit supplied with 100A Type A RCD • Available with type 2 SPD • Each consumer unit supplied with spare cover blanks • Lockable covers also available, see accessories section
Product Code
Unpopulated + 100A Type A CF6R14 CF9R17
CF12R110
Modules
6 9
12
Unpopulated + Surge Protection Device CF9R1S6 CF12R1S9
9 12
Ways
4 7
10
6 9
RCD
100A 100A 100A
100A 100A
SPD Type 2
- - -
Y Y
IP
IP20 IP20 IP20
IP20 IP20
Cover Blanks
2 2 2
2 2
18th
Understanding the changes Amendment 4 to BS 7671:2018 Edition Wiring Regulations
FREE accredited CPD course for anyone involved with the design, installation, inspection, certification and approval of electrical installations.
Find out more
www.luceco-academy.com
12
BG Circuit Protection
BG Circuit Protection
• FREE CPD TRAINING COURSES • FULLY ACCREDITED
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32