94
INTERIORS
Designing for whole-life safe water management
I
n healthcare and other managed-water environments,
design and specifi cation can infl uence how easily water outlets can be effectively commissioned, fl ushed,
inspected,
throughout their service life. For showers,
isolated, decisions made during tested,
maintained and recommissioned that means considering
more than immediate user safety and functionality. Access to services, suitable isolation points and provision for effective fl ushing all contribute to practical long-term water management.
Horne pre-plumbed shower panels bring these requirements together within a factory- assembled, pressure-tested unit. Because the pipework and service connections are already assembled within the panel, there is less on- site assembly and fewer wall penetrations – simplifying installation, coordination and future access. Accessible low-level servicing and isolation points support maintenance, sampling,
pressure and temperature
testing and performance verifi cation, while also simplifying decommissioning and recommissioning when outlets are temporarily taken out of use. Provision is made for elevated-velocity Unlike routine,
(EV) fl ushing. fl ushing,
or ‘duty’ which principally turns over
and replaces stagnant water, EV fl ushing specifi cally increases shear forces at the internal pipe surfaces, helping to disturb, erode and mobilise accumulated material and biofi lm from local pipework. Where a further level of water-hygiene control is desired, Horne -T4 and -T9 shower models incorporate the patented In-line Thermal Disinfection Unit (ILTDU), enabling targeted thermal disinfection of the mixed- water pathway through to the outlet using the existing >60°C system hot-water supply. These measures can be particularly valuable where occupancy fl uctuates,
or
facilities experience periods of reduced use, temporary shutdown or seasonal closure.
01505 321455
www.horne.co.uk b.link/NBS_Horne
By incorporating access, ease of fl ushing and maintainability
from the outset,
shower specifi cation can support effective water management from commissioning through long-term operation,
decommissioning and subsequent recommissioning. Horne
shower ‘families’ are available
on NBS Source, where specifi ers can access product information, detailed specifi cation data and BIM objects.
temporary
WWW.ARCHITECTSDATAFILE.CO.UK
ADF OCTOBER/NOVEMBER 2026
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108