SAFETY & SECURITY


visitors to the primary access point where management or oversight is in place. External spaces must also support safe evacuation and allow clear access for emergency services.


The entrance sequence – from the external approach to the internal foyer – should be considered as a unifi ed spatial experience, not single architectural features.


Safety considerations


Fire safety remains fundamental in entrance design. Door systems must support emergency escape, with powered pedestrian doors confi gured to release, unlock or fail safe during evacuation. Smoke control or compartmentation strategies may depend on doors performing specifi c functions during a fi re.


Ensuring any added security features do not impede emergency egress is especially important in public buildings or spaces with large occupant numbers, where evacuation routes must remain clear and reliable.


Shared & multitenant buildings Design challenges become more complex in multi-tenant or shared buildings. A single primary entrance may serve several


organisations, each with its own security expectations. ‘Speed lanes’ or access control points may regulate movement to different areas while maintaining the welcoming character of the overall space. In these buildings, the foyer becomes a transitional zone that must balance open circulation with controlled access. Spatial planning is essential to ensure that security features do not create bottlenecks or obstruct escape routes.


Designing for change


Buildings evolve over time and entrance systems must be fl exible enough to adapt. Changing occupancy patterns, new building uses or shifting security expectations may alter how entrances need to function. For example, an offi ce building may later incorporate public services or community facilities, introducing new demands for access management. In refurbishment or adaptive reuse projects, architects must reassess whether existing entrances still meet the building’s operational and safety requirements.


Darren Hyde is technical & training manager at ADSA


ORION ICE keeps criminals out in the cold V


BH has developed the greenteQ ORION ICE 3-star profi le cylinder for UK door manufacturers.


The cylinder is fully accredited to the latest TS007:2024 kitemark,


providing protection


against thermal (freeze) and glue attacks, picking, drilling, bumping and snapping, all without the need to add supplementary security devices. ORION ICE is available in key/key and thumb turn options, in singles and keyed alike pairs, and each cylinder is supplied with fi ve keys as standard, which is a real benefi t to end users. VBH’s proteQ10 security guarantee has been upgraded for customers using ORION ICE. It will pay the end user an increased £5000 in compensation if a break in within the UK is achieved as a direct result of an ORION ICE cylinder being snapped.


ORION ICE is recognised by Secured by Design as a Police Preferred Specifi cation product. Richard Gyde,


managing director at


VBH, says, “ORION ICE is the fi rst of our ICE range of security products, which will protect users In Case of Emergency long into the future. “Our original Orion 3-star has been a great


success and is hugely popular within the door and locksmith markets. Companies who use ORION ICE benefi t from the fact that the cylinder builds on the qualities of Orion, and features additional innovative technology that protects against the new thermal (freeze) and glue attack methods. “We know that ORION ICE not only passes


the testing required to meet the requirements of TS007:2024, but that it keeps criminals out in the cold in the real world, too.


Door


manufacturers who fi t ORION ICE can be confi dent that they are achieving the highest standard of door security.”


01634 263263 www.vbhgb.com


WWW.ARCHITECTSDATAFILE.CO.UK


ADF JUNE 2026


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68