The devil is in the detail D
espite what most people believe, toxic smoke is the cause of the most deaths in fires, as opposed to the
fire itself. So what constitutes a fire door? The BWF Fire Door Alliance states the term usually refers to a fire door leaf which is the main component installed into a fire-rated frame, along with ‘essential ironmongery’ to make the door perform correctly in the event of a fire.
However therein is the challenge – when not required to be a fire door it must still perform everyday functions of providing safety, security, privacy, separating different areas and reducing noise in a building. When an architect specifies door products, it is imperative that as well as achieving the everyday design requirements, factors relating to fire resistance are also a key consideration in order to achieve regulatory compliance.
Under the spotlight
Apart from the frame and door leaf, a fire door includes a door closer, smoke seals, hinges, push pads or handles, signage, and maybe a vision panel. Each and every component must be fit for purpose; should any component fail then the whole fire door assembly could fail. And any item that is badly fitted or wrongly specified could contribute to the spread of fire. For each part of the fire door there are standards that must be adhered to. The door and frame should be installed securely and plumb and true with a maximum gap of 3 mm to all sides for a fire door with smoke protection (for a general fire door the gap can be up to 10 mm). The door closer is an important part of the fire door assembly and it is critical to specify a suitable unit and ensure minimum size EN 3 is used.
All doors must be fitted with intumescent seals – they play a major role in fire safety as they will expand to around 10 times their volume when significant heat is applied.
Hinges are a critical part of a door, carrying its weight and allowing free
ADF JUNE 2022
Richard Richardson-Derry of GEZE UK looks at how a properly fitted fire door with the appropriate components can give occupants vital time to escape in the event of a fire
movement of the door leaf but also helping to keep the door straight during a fire episode. There should be three hinges in a fire door up to 2,100 mm high. For doors over 2,100 mm high, exceeding 150 kg, or over 100 mm wide there should be four. All hinges for fire doors should be made of steel or stainless steel and have a melting point of no less than 800°C. All relevant push pads, handles and kick plates must have the required test data and standards and should have a melting point of at least 800°C. Locks need to comply with BS EN 12209 and lever handles with BS EN 1906.
Signage on a fire door is required, such as ‘Fire Door Keep Shut’ or ‘Fire Door Keep Locked’. They need to conform to BS 5499: ISO 7010. Vision panels can be introduced to a door specification for reasons of safety,
WWW.ARCHITECTSDATAFILE.CO.UK
For each part of the fire door there are standards that must be followed
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84