FOCUS ON HAEMOSTASIS
the study enabled the laboratory to demonstrate to clinical colleagues the good correlation between POC and accredited laboratory results. This supported the
introduction of the Quantra POC solution into surgical protocols, significantly reducing their reliance on blood products. The laboratory noted that there was no point in risking patient safety by giving unnecessary blood products if they could provide data that better informed medical decision-making when a critical bleed occurred. Three years on, consultant anaesthetist Dr Mario Ferrante at New Cross relies on Quantra to support him when faced with acute perioperative situations. Talking about his recent experiences he explained: “…within five minutes we know exactly how to treat the patients. Without the Quantra results it is likely that they would have (been) given more products.”
Reducing use of blood products The UK’s Royal College of Obstetricians and Gynaecologists (RCOG) defines PPH as blood loss of ≥500 mL within 24 hours of vaginal delivery, or ≥1000 mL after Caesarean delivery. Blood loss that is severe (>2000 mL) or massive (>2500 mL) is defined, irrespective of the means of delivery.
Observational findings from a 10- year study across Wales showed that a fibrinogen level of 1.0–1.5 g/L is likely to be too low for adequate haemostasis during ongoing PPH.5
Left: The Quantra POC analyser. Above: Easy-to-read dials display QStat parameters.
The 2020 US quality assurance study11 also confirmed the Quantra’s precision with data demonstrating that the system was “able to generate results with high precision, while operating at the POC”. It showed that the CV for total imprecision was 3.6% to 8.0% for all measured parameters.
marker for increasing PPH. Its findings have already led to new risk assessment strategies.9
These start with the need to
make an early, formal risk assessment of every patient, and they recommend that multidisciplinary clinical care is available at the point of care when blood loss reaches 1000 mL.
Fibrinogen below
3 g/L and especially below 2 g/L is associated with progression of bleeding, increased RBC and blood component requirements, and the need for invasive procedures.6
Data also showed it was possible to achieve a 60% reduction in bleeding of more than 2500 mL and a fall in hysterectomies and intensive care unit admissions. From the laboratory perspective, there was a 30% reduction in the use of blood products.7 The study’s overall aim was to find ways to improve maternal outcomes8 by assessing the value of POCT and to investigate the role of fibrinogen as a
Confidence in POC algorithm In terms of decision-making, it emphasised that having information provided by the cumulative measurement of blood loss was essential. It further advised that this could be facilitated by having access to POCT-guided blood- product decisions using a robust, clinical- based algorithm.10 Willingness to switch to a POCT
protocol as recommended by the Welsh study relies on having confidence in the device. Independent evidence from both a NEQAS evaluation and one carried out in the USA both confirm the precision of the Quantra, again putting it firmly in line with laboratory accreditation standards. The NEQAS report shows that the Quantra cartridge consistently demonstrated robustness and good precision, with a 5% coefficient of variation (CV) and an overall CV range of 2.6% to 6.9%. NEQAS further confirmed that the results would be suitable benchmarks for EQA compliance.
It is recognised that PPH can be exacerbated by coagulopathy, with a decline in fibrinogen levels known to be the first indicator of the condition
WWW.PATHOLOGYINPRACTICE.COM AUGUST 2022
Technological excellence The internal design of Quantra enables opportunities for internal quality control (QC) that are made possible by the ultrasound-based technology within the device. It uses ultrasound to directly measure clot elasticity rather than amplitude. The result is increased sensitivity to early clot formation and also to soft clots, often linked to clinical bleeding. With this approach, every time an ultrasound pulse is transmitted, and echoes are received, the system effectively obtains a ‘line’ image through the sample. This offers unique capabilities to perform more advanced quality checks that are not currently available with other VET devices, especially during the preanalytical and analytical phases of testing.
Other innovations focus on the ease of use and interpretation of results in a fast- moving environment like the operating theatre. The dials on the Quantra display the readings of each of the parameters as numbers (although this can easily be changed to review as curves if desired). The data can also be shared remotely with the laboratory or blood bank through the Remote Desk Viewer, with real-time or historical results assessed from any networked Quantra instrument in the hospital.
The Quantra QStat cartridge has a
role to play in PPH due to its ability to measure fibrinolysis. QStat parameters include clot time (CT), clot stability to lysis (CSL), clot stiffness (CS), platelet contribution to clot stiffness (PCS) and fibrinogen contribution to clot stiffness (FCS).
39
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41