PRODUCTION • PROCESSING • HANDLING


High temperature Coriolis mass flowmeter with


insulation and heating jacket THE FLOWMETER OF CHOICE


Richard Davison explains how high temperature Coriolis mass flowmeters enabled a refinery to manage reprocessing of heavy crude residue


Unlike other refineries that process lighter crudes for the production of conventional fuels, the refinery processes heavy crudes to distil its special products. To increase distillation efficiency, the slop residue of crude oil, the lighter part of crude oil obtained during the distillation process, is also reprocessed. To better handle the variability of the slop oil before reprocessing it, the slop reflux has to be carefully controlled. Slop oil is a challenging medium. It is a thick and viscous fluid by nature and is recirculated at temperatures up to 400°C. Depending on the heaviness of crude oil, the slop reflux can also be corrosive. Te refinery had already tried to master this application using Coriolis mass flowmeters with limited success. Te tested instruments were certified to only 350°C and so were often failing in the application. Te systems design team was therefore


O 36 www.engineerlive.com


ne of Europe’s leading refineries produces speciality oils, with naphthenic oils and bitumen being two of its core business products.


searching for a reliable and accurate Coriolis mass flowmeter to be tested across the complete temperature range on one of its distillation units. In this application, the slop oil was


running at a flow rate of 270-16,000kg/h in a temperature range of 320-400°C at 3.5barg. Density was 758kg/m³ with a viscosity at operating temperature of 5cSt.


THE IDEAL SOLUTION To meet these requirements, Krohne supplied an Optimass 6400 DN50 (2in) high-temperature meter in stainless steel. Tests showed that the Coriolis mass flowmeter was the flowmeter of choice in this challenging application as it delivered the required accuracy even at the maximum process temperature at 400°C. Te flowmeter with twin bent tube design was installed vertically in the insulated slop reflux line. To ensure the consistently high temperature of the medium, the flowmeter was supplied with an insulation jacket and was connected to a heating system. Te


Optimass 6400 was provided as a remote version with the converter to be separately installed 20m from the flow sensor. Te advanced MFC 400 converter


allowed for a smooth set up and configuration. It enabled a seamless integration into the existing DCS (distributed control system) and asset management system of the customer. Te refinery was very satisfied with the


flowmeter. It provided excellent accuracy and repeatability at high temperatures and handled the specific process conditions exceedingly well. It has been very robust and extremely reliable for the customer’s operations. Tis has enabled the system design team to model and optimise the distillation to obtain maximum process efficiency while also helping the company to troubleshoot and solve problems in the distillation column.


Richard Davison is with Krohne. www.krohne.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52