PRODUCTION • PROCESSING • HANDLING
LEAK-FREE PUMPING Rainer Landowski discusses the application of centrifugal pumps for liquid sulphur
Te transport of sulphur often occurs in liquid form at temperatures above 125°C. Viscosity increases abruptly above 150°C. Good transport of liquid sulphur occurs in
S
ulphur is a common element in nature and one of the most frequently used substances in petrochemistry and chemistry.
a temperature range between 125-145°C. Tis narrow range makes the selection of the pump – and especially of its shaft seal – challenging. No seal is really tight. No matter how small the amount of leakage, escaping sulphur will crystallise in the ambient air and gum up the seal. Typically, a steam quench is then used to flush the leakage away from the seal. Ensuring the necessary steam temperature and volume to do this is challenging and not always successful. Sulphur residues are always found in the vicinity of such pumps, and these must be removed at great expense. One solution is shaft sealing systems; but these are prone to failure and require a lot of maintenance. What could be more obvious, therefore,
Sulphur pump with worn mechanical seal
than to replace the shaft seal with a magnetic coupling? Magnetic couplings operate leak-free and completely seal the pump chamber from the atmosphere. Sulphur cannot escape from the pump. Te drive torque of the motor is transmitted to the pump rotor without contact by a strong magnetic field. In the air gap between the two magnetic coupling halves, a containment can statically seals the pump from the atmosphere.
Magnetically coupled sulphur pump 34
www.engineerlive.com
TEMPERATURE CHECK For the overall “sulpur pump” system to work, we need a heat balance for the pump to ensure that the minimum temperature of 125°C is safely reached. At the same time, the maximum sulphur temperature of 145°C must be prevented from being exceeded by the internal
losses of hydraulics and magnetic coupling.
Te pump body is designed with heating chambers. Te heating chambers are heated with steam at a temperature of approximately 135°C. Te heating chambers are generously dimensioned to achieve the fastest possible heating of the entire pump body. Reaching the working temperature is verified by means of PT-100 in the area of the pump’s sliding bearing. Special attention must be paid to the containment can. Te rotating magnetic field induces eddy currents in a metallic containment can, which are normally considered a loss. However, when pumping liquid sulphur, they help to heat the sulphur even in this narrow gap and keep it pumpable. A heating chamber charged with steam in close proximity to the magnetic gap ensures that the eddy currents do not cause the liquid sulphur to overheat and thus increase in viscosity. With a little experience, the sizing of the various temperature control sources is easy to perform. With the help of a temperature
measurement inside the magnetic gap, this function can be controlled very easily and accurately. Magnetic drive pumps are now established in many industrial sectors and have pushed back complex mechanical seal systems. In the chemical industry, magnetic drive pumps account for more than 30% of new investments. In many cases, sulphur pumps are operated in countries that are still at the beginning of their industrial development. Plant cleanliness and reliability may not have the priority there that is expected in Europe. However, globalisation is leading to world-class production standards even in less developed countries. Magnetic drive pumps help to achieve this more quickly and are no longer complicated at all once their function has been understood.
Rainer Landowski is with Dickow Pumpen.
www.dickow.de
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52