In collaboration with ProtonDx, Alpha Laboratories introduces SmartLid™, an innovative magnetic key and lid system revolutionising the nucleic acid extraction process. This ground-breaking solution is tailored for swift and efficient viral DNA/RNA extraction, streamlining the essential sample extraction steps - Lysis, Wash, and Elution. SmartLid provides a smarter, faster, and eco-conscious approach to handling nucleic acids in molecular biology applications, setting a new benchmark in the field.
SmartLid offers a distinct advantage by delivering high yields of ultra-pure DNA/RNA, enhancing sensitivity for downstream processing and establishing a new standard in nucleic acid extraction efficiency. Utilising cutting-edge superparamagnetic beads, it enables ultra-fast extractions, producing eluted DNA/ RNA from as many as 12 samples in under 10 minutes.
The SmartLid procedure is designed with user-friendliness in mind, necessitating no electricity, minimal pipetting, and just three straightforward steps. This guarantees unparalleled ease-of-use, catering to professionals at various experience levels. It finds applications in PCR, RT-PCR, qPCR, RT-qPCR, LAMP, RT-LAMP, dPCR, RT-dPCR, and other amplification chemistries. Primary sample types encompass cell-free or nearly cell-free liquid media like VTM, eNAT, PBS, water, saliva, serum, plasma, urine, etc.
SmartLid™ is designed with a commitment to minimising plastic waste, featuring cartons and paper inserts made from recycled content that are entirely
recyclable. Furthermore, the reusable magnetic keys play a role in reducing rare-earth waste. More information online:
ilmt.co/PL/JRzB
61964pr@reply-direct.com Advanced thermogravimetric analysers for proximate analysis
Elite Thermal Systems Ltd UK has launched the TGA et500 and TGA et250. Elite Thermal’s Thermogravimetric Analysers (TGAs) are high-performance instruments that measure the weight change of a sample as a function of temperature. They are used for applications including coal, coke, cement, catalyst, feed, and foodstuffs.
Both models of Elite’s TGAs come with an integrated balance that combines Drying, Ashing and Weighing processes. This improves efficiency, precision, and provides high throughput. Elite’s TGAs are compliant with international standards including ASTM, ISO, DIN, EN and more.
TGA et500 includes a second carousel for automatic placement and removal of crucible lids for fully automatic analysis. TGA et250 is a cost-effective instrument with manual handling of crucible lids.
The TGA et500 features a dual carousel design, streamlining the automatic placement and removal of crucible lids. Equipped with a programmable furnace, this advanced thermogravimetric analyser ensures precision in thermal analysis. The thermally isolated balance, with a sensitivity of 0.0001g, enhances accuracy in weight measurements. Capable of analysing up to 19 samples, the TGA et500 offers versatility for various applications, including organic, inorganic, and synthetic samples. Its Windows-based software facilitates seamless operation with 16 editable programs and LIMS connectivity. The TGA et500 is designed to assess crucial parameters such as moisture, volatiles, ash, loss on ignition (LOI), and fixed carbon, providing comprehensive insights into sample composition and behaviour.
Elite Thermal Systems Ltd UK has scaled-up their operations by expanding to a new manufacturing facility. More information online:
ilmt.co/PL/4mqd and
ilmt.co/PL/m4Dx
ADVERTORIAL Precision liquid dosing and transfer
diaphragm pumps Simple, intuitive, highly precise
EASY,
INTUITIVE HANDLING!
Whether chemical reactors, electrolysis, redox flow, polymer chemistry or transferring from large containers into small ones: in numerous laboratory applications, precise dosing and constant transfer of liquid media is crucial for optimum results. KNF diaphragm liquid dosing and transfer pumps always deliver absolute accuracy and therefore reliably reproducible outcomes.
SIMPLE DOSING & TRANSFER OF LIQUIDS
Chemical resistant diaphragm liquid dosing and metering pumps.
Dosing pump fl ow rates of 0.03 – 100 ml/min Easy calibration for precise results Long-term stable repeatability ±1 % Quiet operation, low vibration and small footprint
Transfer pump fl ow rates of 0.2 – 3.0 l/min Adjustable using a control knob
Suitable for chemical reactors, electrolysis, redox fl ow, polymer chemistry and to transfer from large to small containers.
knf.com
When selecting the optimum pump for a laboratory application, the desired dosing volume as well as the type of chemicals and the type of control (manual and/or external) play an important role in making the right choice. KNF diaphragm liquid pumps allow users to choose the pump that is best suited to their individual needs.
With easy calibration and consistent flow rates of 0.03 to 100 ml/min, the SIMDOS® dosing pump adapts to any dosing volume and guarantees highly precise results and a long-term stable repeatability of +/- 1 per cent. Small footprint, quiet operation and low vibration combined with maximum performance and intuitive operation make it the first choice for laboratory users with the highest demands on precision and efficiency.
The LIQUIPORT® transfer pump is a safe and reliable option for the efficient transfer of
liquids, offering flow rates from 0.2 to 3.0 l/min. The desired flow rate can be adapted precisely to any requirement and can be set easily and intuitively using the adjustable control knob.
Various material combinations, including PTFE, PVDF, PP and FFKM, ensure optimum chemical resistance of the SIMDOS®
and LIQUIPORT® pumps, making them suitable
for use with a wide range of liquids in the laboratory. Both pumps are safe to run dry, self-priming and maintenance-free. Equipped with a manual LCD graphic display or an external control option via RS-232, they offer easy and convenient operation at all times.
More information online:
ilmt.co/PL/vzXD and
ilmt.co/PL/4mLd 62011pr@reply-direct.com
62033pr@reply-direct.com
KNF-005-2024_LAB-Anz_Fluessigkeitspumpen_105x148_EN_rz.indd 1
07.02.24 08:46
LABMATE UK & IRELAND - APRIL 2024
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48