7B-33 Air Conditioning System:
Installation
Reverse removal procedure noting the following
instructions.
• Use new O-ring.
• Apply compressor oil to O-ring.
• Tighten relive valve to the specified torque.
Tightening torque
Relief valve (a): 8 N·m (0.8 kg-m, 6.0 lb-ft)
(a)
I4RS0A720049-
• Evacuate and charge the A/C system referring to
“Evacuation” and “Charge” in “Operation Procedure
for Refrigerant Charge: ”.
Specifications
Tightening Torque Specifications
S4RS0A7207001
Fastening part
Tightening torque
N
Note
⋅m kg-m lb-ft
Cap 3.0 0.3 2.5 )
A/C refrigerant pressure sensor 11 1.1 8.0 )
Armature plate bolt 15 1.5 11.0 )
Relief valve 8 0.8 6.0 )
NOTE:
The specified tightening torque is also described in the following.
“Compressor Assembly Components: ”