reduces emergency call-outs and supports troubleshooting, even at night, while keeping operators safe. Monitoring hydraulic parameters (pressures, temperatures, fl ow rates) also enables early detection of abnormalities and helps anticipate potential leaks, further improving overall reliability. For cooling, FCCI initially relied on proven refrigerants such as R-513A and R-448A before gradually integrating very low GWP A2L refrigerants such as Solstice L40X (R-455A) and R-454C. This transition is taking place without any technological disruption, using simple, modular and easy-to-maintain machines.
The Super U in Léognan Commissioned several years ago, the Super U installation in Léognan has provided practical feedback on the reliability of the indirect architectures developed by FCCI. Used daily since commissioning, it has demonstrated the robustness of the combination of low refrigerant charge and distribution via Greenway Neo over time, in terms of energy performance, maintenance, and service continuity. For this local supermarket, FCCI deployed a complete
indirect architecture for medium-temperature refrigeration with two 50-horsepower Bitzer units, each supplying a plate heat exchanger. Each circuit operates on R-513A, with a charge limited to about 45 kg of fl uid per unit, i.e., a cooling capacity of around 70 to 80 kW at minimum charge. Two buff er tanks provide thermal inertia; then secondary pumps distribute
Download the ACR News app today 28-29
acrspmclimalife.indd 29
Greenway Neo N to all cabinets and cold rooms via several hydraulic networks.
The central kitchen of Saint-André The more recent Saint-André central kitchen is an example of the new generation of FCCI facilities, incorporating very low GWP refrigerants and even lower charge sizes from the design stage onwards. This project builds on the experience gained at the fi rst sites to further improve energy effi ciency, health and safety, and ease of operation. The central kitchen is equipped with seven medium-
temperature cold rooms powered by an indirect Greenway Neo N circuit. Two Bitzer Ecolite condensing units provide cooling using R-454C (A2L), with a charge of about 15 kg of refrigerant per unit. The refrigerant is fully contained in the technical room, while the hydraulic network distributes the chilled fl uid to the evaporators in the rooms. The installation includes two plate heat exchangers, a
buff er tank of approximately 1,000 litres, and primary and secondary pumps. This architecture greatly limits the presence of refrigerant in food preparation areas, reduces health risks and simplifi es maintenance operations. Low-temperature cooling is handled separately using direct expansion with R-455A, ensuring robust and stable operation. The system off ers excellent thermal performance, simplifi ed maintenance and safe operation, perfectly suited to the constraints of commercial catering.
www.acr-news.com • November 2026 29 26/10/2026 12:58
“The fi rst store to use Greenway Neo N was a 5,000 m² Leclerc hypermarket. Since then, we have fi tted out numerous stores with smaller sales areas in line with market trends. After several years of operation, no signifi cant deterioration of the fl uid or the networks has been observed."
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36