FANS DATA CENTRES
Cooling for the AI era
As AI and cloud services drive demand for data capacity higher, cooling has become one of the most critical systems in any data centre. The challenge is no longer simply removing heat but designing cooling systems that can adapt as processing demands evolve. Cliff Jones, Head of Applied at Daikin, looks at what it takes to get it right, from technology choice to controls and specialist support.
"Data centre projects are complex, and technical and design support is important throughout."
N
early every email, search and streamed fi lm relies on a data centre somewhere. Demand for capacity has risen sharply with the growth of artifi cial intelligence
(AI) and cloud storage, and the facilities meeting it vary enormously, from a handful of server racks in an offi ce building to hyperscale sites built purely for data processing. The priorities, though, are the same at every scale: keep the servers running without interruption and get rid of the heat they produce. Cooling isn’t a supporting service in a data centre. If it fails or underperforms, the servers and everything running on them are at risk.
Matching the technology to the application
For smaller server and UPS rooms, direct expansion (DX) systems are often the best fi t. Some DX units include dedicated server room settings as standard, providing the control logic the space needs without additional hardware or complex controls. Larger facilities typically use chillers serving computer room air handling (CRAH) units and fan walls which draw warm air from the data hall, pass it across chilled water coils and return cooled air to the space. With increased rack loads, in row coolers and rear door heat exchangers are used for AI retrofi ts.
16 November 2026 •
www.acr-news.com 16-17
acrdcdaikin.indd 16 AI is beginning to change this. High-performance processors
generate far more heat than conventional servers, and air cooling alone often can’t cope. Increasingly, operators add direct-to-chip liquid cooling alongside it, typically via a coolant distribution unit (CDU). The CDU connects to the main facility water system and supplies an isolated secondary coolant circuit that delivers cooling directly to the chips. This hybrid liquid-and-air approach, with CDUs and CRAHs, is becoming a common AI thermal system architecture.
Effi ciency through intelligent control High energy prices and closer scrutiny of the sector’s environmental impact mean effi ciency must be built in from the outset. Variable frequency drive (VFD) compressors help signifi cantly, but controls can off er some of the greatest opportunities to reduce energy use. Redundancy is a good example. Resilience and uptime are
classic requirements in data centres; however, they don’t always require backup units sitting idle. Instead, the cooling load can be spread across all available units so each runs at part load, where the plant is most effi cient. Free cooling off ers further savings. When outdoor
temperatures are low enough, ambient air can cool the water circuit, signifi cantly reducing compressor run time. The higher
Download the ACR News app today 30/10/2026 10:34
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36