DATA CENTRES FANS
"High-
the chilled water temperature can practically be set, the more free cooling is available. Data centres also produce waste heat that can be
recovered and fed into district heat networks. Even where a connection isn’t yet viable, it makes sense to allow for one so it can be added in future.
Designed for a specialist environment Data centres are sensitive environments, and the cooling plant serving them needs to be designed accordingly. For instance, active harmonic fi lters built into the units prevent harmonic distortion from components such as VFDs from aff ecting power quality across the site and the network. Computing technology is developing so quickly that data
centres built now will likely need modifi cation in the future, including those designed around a combination of CRAH air cooling and CDU liquid cooling. Specify systems so the balance can move toward liquid cooling as AI loads increase, with minimal additional investment.
Closing the refrigerant loop Many older data centres could be operating far more effi ciently. When their cooling systems are due for replacement, operators should consider how to increase
Download the ACR News app today 16-17
acrdcdaikin.indd 17
performance and capacity by looking at facility water temperatures, rather than simply replacing like for like. Refurbishment also creates an opportunity to reuse
refrigerant. Under schemes such as Loop by Daikin, refrigerant is recovered from the units being removed and reclaimed to the same standard as virgin product so it can be used again. The new units are then administratively allocated previously reclaimed refrigerant.
The value of specialist support Data centre projects are complex, and technical and design support is important throughout. A manufacturer with a dedicated data centre team brings in-depth sector knowledge and experience gained on other projects. As computing loads continue to evolve, the most successful data centre cooling strategies will combine reliability, effi ciency, and the fl exibility to adapt to future requirements. That depends on specifying the right equipment and having experienced support from specifi cation and design through installation, commissioning, ongoing maintenance, and future upgrades/ replacements to align with rapidly changing needs.
performance processors generate far more heat than conventional servers, and air cooling alone often can’t cope."
www.acr-news.com • November 2026 17 23/10/2026 13:26
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36