PARTNER FOCUS


Carrier’s new AquaForce 30XF air-cooled screw chillers for data centres are equipped with an integrated hydronic free-cooling system and variable-speed inverter drives.


Carrier launches AquaForce 30XF chiller range for data centres


Carrier has launched a new range of high-performance chillers for data centres, designed to minimise energy use and carbon emissions while cutting running costs for operators. Available in capacities from 400kW to 2100kW, the Eurovent and AHRI certifi ed units are based on proven Carrier screw compressors, ensuring effi cient, reliable operation and long working life.


C


arrier’s new AquaForce 30XF air-cooled screw chillers are equipped with an integrated hydronic free-cooling system and variable-speed inverter drives, which combine to deliver energy savings of up to 50% during total free-cooling operation. The chillers, available on ultra-low global warming potential


refrigerant HFO R-1234ze(E), off er excellent resilience with an ultra-fast recovery system that, in the event of a power cut, can resume 100% of cooling output within two minutes of power being restored. This ensures cooling is maintained for critical servers and data protected. The chiller can operate in a wide range of ambient conditions, from -20 to 55°C, making it suitable for use in cold, temperate and hot climates, while Carrier’s smart monitoring system ensures optimum effi ciency and performance. Variable-speed fans further increase energy effi ciency and support quiet operation at part-load. To further enhance chiller performance, the units are equipped with a dual power supply (400/230V or 400/400V) with electronic harmonic fi lter. The fi lter automatically monitors and maintains the quality of the power supply, preventing damage to the chiller’s electrical components and improving overall system effi ciency. The hydronic free-cooling system is available in a glycol- free option for applications where glycol cannot be used. This


Download the ACR News app today


operates with glycol in the outdoor unit only, and enables the size of the glycol-free indoor units to be reduced by up to 15%. “The new AquaForce 30XF has been designed specifi cally to meet the strict environmental, effi ciency and reliability requirements of data centre applications, and ensure servers keep running cool around the clock,” said Raff aele D’Alvise, Carrier HVAC marketing and communication director. “The chiller helps data centre operators achieve their budget and sustainability goals by reducing energy consumption and carbon emissions, while providing excellent resilience and extended working life.” The AquaForce 30XF is part of Carrier’s comprehensive


range of cooling solutions for data centres, which includes AquaSnap 30RBP air-cooled scroll chillers, AquaEdge 19DV water-cooled centrifugal chiller, AquaForce 61XWH-ZE water- cooled heat-pump, plus computer room air conditioners, air handlers and fan-walls, all supported by Carrier BluEdge lifecycle and service and support to maintain optimum performance. These products support Carrier’s 2030 Environmental, Social & Governance (ESG) goal of helping customers avoid more than one gigaton of greenhouse gas emissions by 2030.  www.carrier.com/commercial/en/eu/products/air- conditioning/air-cooled-chillers/30xf/


The hydronic free-cooling system is available in a glycol-free option for applications where glycol cannot be used.


www.acr-news.com • April 2024 23


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40