This page contains a Flash digital edition of a book.
Legionella – is your business managing the risk?


TME is the UK specialist in temperature test and measurement equipment for the prevention of Legionnaires’ disease. How does its legionella water temperature range help businesses manage the risk?


Legionella risk management is probably one of the most demanding compliance issues in FM, affecting a surprisingly wide range of buildings. The bacteria may be present in stored or circulated water – typically supplied to showers and taps but also storage tanks, calorifiers and air conditioning systems. It is the inhalation of fine water droplets or spray containing this bacteria which causes Legionnaires’ disease.


Who is at risk? Risk of contracting the disease increases with age and also for anyone with reduced immunity – putting hospitals, care homes and schools under the spotlight. But many other buildings are affected - typically hotels (the source of the first known outbreak) and leisure facilities. Outbreaks have also been traced to restaurant air conditioning outlets, rooftop water tanks in office blocks and factory cooling towers. TME thermometers help a diverse range of businesses to manage this risk - from accountancy firms to marinas.


Why is water temperature


important? To comply with legislation, all businesses are required – regardless of size or type – to undertake a risk assessment and then manage and maintain risk reduction procedures. Legionella bacteria multiplies in tepid water - so a well-established method of reducing risk in many cases is to maintain an effective water temperature testing regime.


The HSE’s ACOP L8 recommends that hot water in a building should be stored above 60°C and distributed above 50°C (or 55°C for care homes), and cold water distributed below 20°C. Water outlets – especially sentinel points - must be routinely monitored to ensure safe temperatures.


Large FM companies are responsible for rigorous estate-wide testing regimes. Other businesses use independent water specialists to undertake a full legionella risk assessment periodically, but carry out routine temperature spot checks in-house. Either way, easy to use equipment, requiring minimal training is a must.


Specialist Solutions TME’s MM2008 Legionella Thermometer with in-built timer is manufactured with a 1 and 2 minute countdown facility – a feature specifically designed to speed up and simplify the timed temperature tests recommended for taps and showers.


Jackie Winn, Director, J W Safety Solutions Ltd, works closely with local authorities on legionella risk control. “Having a built-in timer is a fantastic idea for water testing – much better than trying to hold a thermometer, a timer, a clipboard and a pen all at the same time!”


TME also pioneered the first dual purpose surface/immersion probe – its KS01-S offers the fastest tests for running water, pipe surface and calorifiers, by eliminating the need to swap between different probes. And its CLEGK2 Kit – which combines the MM2008 and KS01-S - is one of the most efficient methods for testing both running water and pipe surfaces. Chas Thompson, Operations Manager, Freeston Water has many years’ experience in the field. “It’s a great piece of kit – especially for businesses who do their own testing because the thermometer timer buttons makes it easier to learn and the dual purpose probe makes the job much faster.”


Hard to reach temperature points Many buildings have boxed-in TMVs, high-level water storage tanks and calorifier feed and return pipes. These problem test points can


be more labour intensive requiring ‘working at height’ procedures to be followed or the building and dismantling of cosmetic panels. TME’s TCWALLPORT system uses low cost fine wire temperature sensors connected to wall-mounted thermocouple monitoring points. This system combined with a high accuracy thermometer like the MM2008 produces an instant temperature reading from up to 20 meters away with no loss of accuracy.


Paperless recording Paperless recording of temperature tests provides ultimate peace of mind, being less vulnerable to human error and more cost effective over time. TME is at the forefront of paperless recording, with the introduction of handheld logging thermometers enabling 1,000s of locations and temperatures to be uniquely identified, logged, stored and downloaded to PC/PDA using open source software. The company’s MM7000/05 and MM7100/7105 barcode scanning thermometers feature programmable alarms with a choice of either Bluetooth communication or USB connection.


Continuous monitoring The latest addition to TME’s specialist legionella temperature range is a customised solution combining continuous monitoring with handheld spot checks, providing the best of both worlds and keeping all paperless records in one place. Users choose from a combination of fixed sensors and handheld probes enabling continuous monitoring of water flow and temperature within pipework as well as handheld running water tests. All results are streamed to a single database using cloud-based wireless monitoring with no installed software required.


For more information contact TME at


sales@tmethermometers.com 01903 700651. TME – When temperature matters


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108