Appliance / Machine / Switchboard Safety
MI 3310A SigmaGT and MI 3310 SigmaGT PAT TESTERS
The MI 3310 / MI 3310A SigmaGT is a multifunctional portable test instrument intended to perform all measurements for complete testing the electrical safety of portable electrical equipment. Along with numerous features like dual power supply support, built-in battery charger, lightweight design, large bright LCD, soft Qwerty keypad, internal memory for up to 6000 results and Bluetooth technology, the instrument offers innovative solution for RCD protected cords testing and enables testing of fixed appliances. Powerful data management PC software PATLink PRO enables upload and download of test results and parameters for further data handling, trend analysis and test report creation.
MEASURING FUNCTIONS:
• Earth bond resistance with 10 A (MI 3310A);
• Continuity test with 200 mA; • Insulation resistance; • Insulation resistance of isolated ac- cessible conductive parts;
• Substitute leakage current; • Substitute leakage current of isolated accessible conductive parts;
• Differential leakage current; • Touch leakage current; • IEC cord polarity test; • Leakage and load currents with cur- rent clamp;
• RCD and portable RCD testing; • Functional test.
KEY FEATURES:
• Autosequencing: pre-programmable VDE compatible autosequences, up to 50 custom prepared autosequences and barcode autotests speed up testing and ensure that no tests are missed.
• Active polarity: innovative solution for testing of RCD protected cords while voltage is applied to the tested item.
• Dual powered: instrument can be powered from both internal battery and mains supply.
• Fixed appliance testing: additional in- puts and optional accessories enable testing of fixed installed appliances.
• Scan and test: optional barcoding sys- tem and PASS / FAIL barcode label print- ing make retesting quick and simple.
• RFID: support for advanced RFID iden- tification system.
• Bluetooth communication with printer and barcode scanner.
• Project uploading: previous test data can be uploaded for fast retesting of the object.
• Trend functionality: test results can be uploaded from PC to the instrument for comparison between old and new test results on site.
• Memory: up to 6000 test results with parameters can be stored into memory and downloaded to the PC with the help of PC SW PATLink PRO.
• User friendly: large LCD screen, full QWERTY keyboard, help screens and warnings make handling the instru- ment very simple and clear.
3. 6
• Clamp leakage current measurement: quick measurement of leakage current with current clamps directly on power supply cable without disconnection of appliance from mains.
• RCD testing: instrument enables test- ing of parameters of RCDs and port- able RCDs.
• PC SW PATLink PRO included in the standard set enables downloading, viewing, printing of test results and exporting of data to spreadsheet ap- plications.
• PC SW PATLink PRO Plus enables ad- vanced analysis of test results, upload of structures and data upload to the instrument for on site comparison of old and new results, upload of pre-pro- grammed custom autosequences and creation of professional test reports.
APPLICATION:
• Professional PAT safety testing; • General PAT safety testing; • Multi-location PAT safety testing.
STANDARDS: Functionality:
VDE 0404-1; VDE 0404-2; VDE 0701-0702; EN 60204-1 Ed.5; EN 60439; EN 61439-1; AS / NZS 3760; NEN 3140 Electromagnetic compatibility: EN 61326-1 Safety:
EN 61010-1; EN 61010-031; EN 61010-2-032
Accessories: page 3.26
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136 |
Page 137 |
Page 138 |
Page 139 |
Page 140 |
Page 141 |
Page 142 |
Page 143 |
Page 144 |
Page 145 |
Page 146 |
Page 147 |
Page 148 |
Page 149 |
Page 150 |
Page 151 |
Page 152 |
Page 153 |
Page 154 |
Page 155 |
Page 156 |
Page 157 |
Page 158 |
Page 159 |
Page 160 |
Page 161 |
Page 162 |
Page 163 |
Page 164 |
Page 165 |
Page 166 |
Page 167 |
Page 168 |
Page 169 |
Page 170 |
Page 171 |
Page 172 |
Page 173 |
Page 174 |
Page 175 |
Page 176