Electrical Installation Safety MI 3121H 2,5 kV Insulation / Continuity


The MI 3121H Smartec 2,5 kV Insulation / Continuity is the portable measuring instrument for complete diagnostic testing of insulation and continuity measurements. Due to insulation resistance measurement with the test voltages up to 2.5 kV (measuring range is up to 100 GΩ) and calculation of PI and DAR indexes the instrument is suited for testing insulation of cable lines, current and voltage transformers, electric motors, etc. Due to configurable limits the instrument enables PASS / FAIL evaluation of test results which is accompanied with bright green or red light of LEDs. Additional features include magnetic holder for fixing the tester on the metal surface and built-in charger. The Mi 3121H is compatible with EuroLink PRO software which enables downloading and analysis of test results and creation of professional test reports.


MEASURING FUNCTIONS:


• Insulation resistance with DC voltage up to 2.5 kV;


• Diagnostic test (PI, DAR calculation) • Continuity of PE conductors with 200 mA test current and polarity change;


• Continuity of PE conductors with 7 mA test current (continuous measure- ment) without RCD tripping;


• TRMS voltage and frequency. KEY FEATURES:


• High measuring range: up to 100 GΩ with test voltage from 100 to 2500 V.


• Insulation diagnostics: PI and DAR calculation for determining if the insu- lation damaged or contaminated.


• Guard test terminal: for elimination of potential surface leakage currents.


• Polarity swap: automatic polarity re- versal on continuity test.


• Analogue scale: measuring results are displayed in numeric and analogue rep- resentation.


• Custom limits: if limits are set on insu- lation or continuity function then large green and red lights of the LEDs will indicate a PASS or FAIL evaluation of test result.


• Safe: suited for testing on CAT IV in- stallations.


• Built-in charger & rechargeable bat- teries: instrument has a built-in charg- ing circuit and comes complete with a set of rechargeable NiMH batteries. Memory: two level memory structure for saving of test results and param- eters.


• Downloadable: downloads via RS232 or USB cable directly to the PC with the help of the PC software EuroLink PRO.


• Easy to use: large bright LCD display and large buttons enable easy handling of the instrument (even while wearing gloves).


• Magnetic holder: magnet for fixing 1. 28


instrument on metal surfaces enables hands-free operation.


APPLICATION:


• Measurement of insulation resistance of transformers, motors, cables, ma- chines, etc;


• Testing on CAT IV installations (distri-


bution side of installations, industrial plants, etc);


• Observation of insulation trends; • Testing of PE conductors continuity and main and supplementary PE connections.


STANDARDS: Functionality:


IEC/EN 61557 Parts 1,2, 4, 10 IEC/EN 60364 VDE 100


BS 7671 17th edition CEI 64.8 Electromagnetic compatibility: IEC/EN 61326-1; Safety:


IEC/EN 61010-1; EN 61010 - 031


Accessories: page 1.48


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148  |  Page 149  |  Page 150  |  Page 151  |  Page 152  |  Page 153  |  Page 154  |  Page 155  |  Page 156  |  Page 157  |  Page 158  |  Page 159  |  Page 160  |  Page 161  |  Page 162  |  Page 163  |  Page 164  |  Page 165  |  Page 166  |  Page 167  |  Page 168  |  Page 169  |  Page 170  |  Page 171  |  Page 172  |  Page 173  |  Page 174  |  Page 175  |  Page 176