Electrical Installation Safety MULTIFUNCTIONAL INSTALLATION TESTERS MI 2086 Eurotest 61557
The MI 2086 Eurotest 61557 performs complete testing of electrical installations and enables a number of additional fea- tures including TRMS current measurement, 4-wire / one clamp / two clamps earth resistance and 4-wire specific earth resistance measurements, illumination measurement and fuse / fault locator function. The handling of the instrument is simple and clear. Each test has its own individual help screen describing how to connect the instrument into the instal- lation and how to perform a measurement. All the results can be saved on the instrument and then downloaded with the help of the EuroLink LITE software to the computer for evaluation and report generation after testing. The MI 2086 Eurotest 61557 performs continuity, insulation, RCD, loop, line, voltage, frequency, earth resistance and phase sequence testing required by the EN 61557 standard.
MEASURING FUNCTIONS:
• Insulation resistance with DC voltage; • Continuity of PE conductors with 200 mA test current with polarity change;
• Continuity of PE conductors with 7 mA test current (continuous measure- ment) without RCD tripping;
• Line impedance; • Loop impedance; • Loop resistance with Trip Lock function; • Voltage and frequency; • Phase sequence; • RCD testing (general and selective, type AC and A);
• Earth resistance (4-wire method, one clamp method, two clamps method);
• Specific earth resistance; • TRMS leakage and load currents; • Overvoltage protection devices testing; • Illumination (option); • Tracing the installations (option); • High resolution loop impedance (mΩ).
KEY FEATURES:
• Fuse location: function enables the lo- cating of fuses / wires / faults with the help of the optional A 1005 Fuse locator.
• Earth resistance measurement: in- strument performs 4-wire earth re- sistance measurement with two ad- ditional rods; 4-wire earth resistance measurement in combination with an additional current clamp; earth resist- ance measurement with 2 current clamps without breaking the loop and 4-wire specific earth resistance meas- urement.
• Downloadable: downloads via RS232 cable directly to the PC with the help of the software included in the stand- ard set.
1. 20
• Help screens: instrument comes com- plete with built-in help screens for ref- erencing on site.
• Polarity swap: automatic polarity re- versal on continuity test.
• Insulation range: wide range of insu- lation test voltages from 50 V to 1000 V, reading up to 1000 MΩ.
• Trip Lock function: RLOOP function performs a loop resistance test with- out tripping the RCD.
• RCD auto: automated RCD testing procedure significantly reduces test time.
• PC SW EuroLink LITE included in the the standard set enables download- ing of test results and parameters and creation of test reports.
APPLICATION:
• Initial and periodic testing of domestic and industrial installations;
• Testing of single and multiphase systems; • Testing of TT and TN systems.
STANDARDS:
Functionality: IEC/EN 61557 Other reference standards for testing: IEC/EN/HD 60364; IEC/EN 61008; IEC/EN 61009; IEC/EN/TR 60755; AS/ NZ 3018; CEI 64.8; HD 384; BS 7671; VDE 0413 Electromagnetic compatibility: EN 50081 - 1; EN 50082 - 1 Safety: IEC/EN 61010-1; IEC/EN 61010- 031; IEC/EN 61010-2-032
Accessories: page 1.48
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136 |
Page 137 |
Page 138 |
Page 139 |
Page 140 |
Page 141 |
Page 142 |
Page 143 |
Page 144 |
Page 145 |
Page 146 |
Page 147 |
Page 148 |
Page 149 |
Page 150 |
Page 151 |
Page 152 |
Page 153 |
Page 154 |
Page 155 |
Page 156 |
Page 157 |
Page 158 |
Page 159 |
Page 160 |
Page 161 |
Page 162 |
Page 163 |
Page 164 |
Page 165 |
Page 166 |
Page 167 |
Page 168 |
Page 169 |
Page 170 |
Page 171 |
Page 172 |
Page 173 |
Page 174 |
Page 175 |
Page 176