Instrumentation
GSM-based autonomous measuring system
Marcel Gautschi reports on an advanced measuring system that features remote data transmission.
T
he use of mobile radio networks and the internet has made it possible to create a virtual combination of widely distributed measuring systems in one location, and make use of the acquired data on the spot.
The GSM reception coverage is so far advanced
and the prices of phone modules, prepaid cards and mobile data transmission are so low that the present solution represents the cheapest, simplest measurement acquisition method, not just for decentralised or remote measuring points, but also easily accessed locations. There are considerable savings due to the reduction in personnel costs. The heart of the measuring system is the GSM-2
DataManager Windows software. It collects the measuring data, monitors and controls the measuring stations and is used to display or automatically process the data stored in a MySQL database. The data transmitted by the GSM-2 is continuously read and stored. This makes it possible to establish at a glance whether all measuring stations are operating correctly.
The monitoring of groundwater levels or the
surface levels of lakes and rivers is a widespread task. To continue using the existing measuring stations, the GSM-2 module has been designed with a diameter that allows it to be inserted directly into the sounding pipes. The entire measuring module is simply inserted into the 2-in diameter sounding pipe and secured by the level sealing cap. After installation, the GSM-2 transmits its configuration with measuring station name and position to the DataManager, which automatically starts to manage the new measuring station. In addition to the RS485 interface, which delivers highly accurate pressure or water level measurements in conjunction with Keller level sensors, the GSM-2 module also features an air pressure and temperature sensor. This makes it possible to take water level measurements using the so-called AA (absolute- absolute) method. Another advantage is that no humidity-sensitive capillary tube is required in the cable of the level sensor. This means the measuring station is designed for reliable use in damp environments and not even short periods of immersion cause it to fail. The two voltage inputs (0-2.5 V), the SDI12 interface and the two digital inputs support the use of all kinds of sensors, from a simple switch contact (digital input) to a complex water analysis unit with up to 10 parameters (SDI12 interface). The GSM-2 supplies the connected sensors with either 12.5 or 3.9 volts. n
For more information ✔ at
www.engineerlive.com/epe
Fig. 2. The GSM-2 can be used for groundwater level measurement.
Fig. 1. The heart of the measuring system is the user-friendly and free GSM-2 DataManager Windows software.
50
www.engineerlive.com
Marcel Gautschi is with Keller in Winterthur, Switzerland.
www.keller-druck.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68