LOAD CELL SENSORS FLC LOAD CELL SENSORS
Three models of s-beam load cell sensors are also available. These are all full bridge, temperature compensated strain gage instruments, designed for force
measurement applications, but suitable for some material testing applications. PREMIUM MODELS
Ideal for low load applications, these sensors have a safe overload rating of 1000% of the sensor's load capacity. SEALED MODELS
These models are suitable for applications in non-laboratory environments where dirt, oil, dust and debris may be present.
ECONOMY MODELS
When price is an issue, these general purpose load cell sensors are economical and suitable for most general purpose force measurement applications.
FLC-P Series - "Premium" S-beam Sensors Model Number
FLC-5P
FLC-10P FLC-25P FLC-50P FLC-100P FLC-250P NOTES
Load Capacity N 5
10 25 50
100 250
2.5 5
10 25
KGF 0.5 1
Safe Overload Full Scale Deflection Height
LBF 1 2 5
11 22 56
0.4 0.3 0.3 0.2 0.2 0.2
0.014 0.012 0.012 0.009 0.009 0.009
63.0 63.0 63.0 63.0 63.0 63.0
2.48 2.48 2.48 2.48 2.48 2.48
Width
59.2 59.2 59.2 59.2 59.2 59.2
Thread
% Full Scale mm inch mm inch mm inch mm 1000 1000 1000 1000 1000 1000
Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1. Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.
FLC Series - "Sealed" S-beam Sensors Model Number
Load Capacity N
FLC-500 FLC-1000 FLC-2000 FLC-2500 FLC-5KN NOTES
500
KGF 50
1000 100 2000 200 2500 250 5000 500
2.33 M6 x 1-6H 2.33 M6 x 1-6H 2.33 M6 x 1-6H 2.33 M6 x 1-6H 2.33 M6 x 1-6H 2.33 M6 x 1-6H
Safe Overload Full Scale Deflection Height
LBF 112 225 450 562
1124 150
0.10 0.15 0.13 0.13 0.13
0.004 0.006 0.005 0.005 0.005
63.0 63.0 76.2 76.2 76.2
2.5 2.5 3.0 3.0 3.0
Width
50.8 50.8 50.8 50.8 50.8
2.0 2.0 2.0 2.0 2.0
Thread
% Full Scale mm inch mm inch mm inch mm 150 150 150 150
Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1. Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.
M6 x 1-6H M6 x 1-6H
M12 x 1.75-5H M12 x 1.75-5H M12 x 1.75-5H
FLC-E Series - "Economy" S-beam Sensors Model Number
Load Capacity N
FLC-50E FLC-100E FLC-200E FLC-500E FLC-1000E FLC-2000E FLC-2500E FLC-5000E NOTES
50
100 200 500
10 20 50
1000 100 2000 200 2500 250 5000 500
KGF 5
Safe Overload Full Scale Deflection Height
LBF 11 22 45
112 225 450 562
1124 150
0.08 0.08 0.08 0.10 0.15 0.15 0.13 0.13
0.003 0.003 0.003 0.004 0.006 0.006 0.005 0.005
63.5 63.5 63.5 63.5 63.5 76.2 76.2 76.2
2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0
Width
50.8 50.8 50.8 50.8 50.8 50.8 50.8 50.8
2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0
Thread
% Full Scale mm inch mm inch mm inch mm 150 150 150 150 150 150 150
Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1. Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.
M6 x 1-6H M6 x 1-6H M6 x 1-6H M6 x 1-6H M6 x 1-6H
M12 x 1.75-5H M12 x 1.75-5H M12 x 1.75-5H
starrett.com
37
LOAD CELL SENSORS
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48