This page contains a Flash digital edition of a book.
LOAD CELL SENSORS


Starrett offers a full range of precision load cell sensors for material testing, force analysis and force measurement applications. Starrett load cells are compliant with IEEE 1451.4 and meet or exceed ASTM E4, BS 1610, ISO 7500-1 and EN 10002-2.


Measurement accuracies of ±0.05% of reading down to 1/100 of sensor capacity may be achieved. Sensors are supplied with a NIST-traceable Certificate of Calibration. Sensors may be used on L3, L2 Plus, L2 and S2 Systems.


ULC AND MLC LOAD CELL SENSORS Starrett ULC and MLC load cell sensors are full-bridge,


temperature


compensated,strain gage instruments designed and optimized for material testing applications. These low profile sensors feature high axial stiffness and minimal deflection at full capacity which leads to improved measurement accuracy.


The ULC provides ultimate measurement performance and are supplied with a standard base plate adapter. Available in capacities from 1.5kN to 50kN.


The MLC are general purpose sensors available in capacities from 125N to 50kN.


ULC Series - "Ultra" Low Profile Sensors Model Number


Load Capacity N


ULC-1500 ULC-2500 ULC-5K ULC-10K ULC-25K ULC-50K


NOTES 1


1500 2500 5000


KGF 150 250 500


10,000 1000 25,000 2500 50,000 5000


Safe Overload Full Scale Deflection Height1


LBF 337 567


1124 2248 5620


11,250 150


0.05 0.05 0.05 0.05 0.05 0.05


0.002 0.002 0.002 0.002 0.002 0.002


63.5 63.5 63.5 63.5 63.5 63.5


2.5 2.5 2.5 2.5 2.5 2.5


Width


104.8 104.8 104.8 104.8 104.8 104.8


4.13 4.13 4.13 4.13 4.13 4.13


Thread


% Full Scale mm inch mm inch mm inch mm 150 150 150 150 150


Dimension includes the base adapter. ULC Series sensors are supplied with the base adapter standard. Load measurement accuracy is ±0.05% of reading down to 1/100 of load cell capacity. Display resolution is 10,000:1. Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.


MLC Series - Low Profile Sensors Model Number


Load Capacity N


MLC-125 MLC-250 MLC-500 MLC-1000 MLC-1500 MLC-2500 MLC-5K MLC-10K MLC-25K MLC-50K


NOTES 1


125 250 500


1000 1500 2500 5000


M16 x 2-4H M16 x 2-4H M16 x 2-4H M16 x 2-4H M16 x 2-4H M16 x 2-4H


Safe Overload Full Scale Deflection Height1


KGF 12.5 25 50


100 150 250 500


10,000 1000 25,000 2500 50,000 5000


LBF 28 56


112 225 337 562


1124 2248 5620


11,250 150


0.08 0.08 0.08 0.08 0.03 0.03 0.03 0.03 0.05 0.05


0.003 0.003 0.003 0.003 0.001 0.001 0.001 0.001 0.002 0.002


38.1 38.1 38.1 38.1


1.5 1.5 1.5 1.5


Width


69.8 69.8 69.8 69.8


63.51 63.51 63.51 63.51 63.51 63.51


2.51 2.51 2.51 2.51 2.51 2.51


104.8 104.8 104.8 104.8 104.8 104.8


2.75 2.75 2.75 2.75 4.13 4.13 4.13 4.13 4.13 4.13


Thread


% Full Scale mm inch mm inch mm inch mm 150 150 150 150 150 150 150 150 150


Dimension includes the base adapter. These MLC sensors are supplied with the base adapter standard. Base adapters are recommended for any MLC sensor. Load measurement accuracy is ±0.05% of reading down to 1/100 of load cell capacity. Display resolution is 10,000:1. Starrett recommends on-site verification of accuracy during installation. Sensor calibration should be performed at least annually.


M6 x 1-6H M6 x 1-6H M6 x 1-6H M6 x 1-6H M16 x 2-4H M16 x 2-4H M16 x 2-4H M16 x 2-4H M16 x 2-4H M16 x 2-4H


36


LOAD CELL SENSORS


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48