12-04 :: April/May 2012
nanotimes News in Brief
plasmon resonance scattering light that is captured by a dark-field microscope (DFM). The RGB (three primary colors, red, green, and blue) chrominance information from the dark-field image can be directly converted into the diameters of the GNPs using the relationship between the particle size and the scattering light peak wavelength. © Analytical Che- mistry
Chao Jing, Zhen Gu, Yi-Lun Ying, Da-Wei Li, Lei Zhang, and Yi-Tao Long: Chrominance to Dimension: A Real- Time Method for Measuring the Size of Single Gold Nanoparticles, In: Analytical Chemistry ASAP, April 14, 2012, DOI: 10.1021/ac203118g:
http://dx.doi.org/10.1021/ac203118g
59
© University of Texas at Austin / R.S. Ruoff research team
Hengxing Ji, Lili Zhang, Michael T. Pettes, Huifeng Li, Shanshan Chen, Li Shi, Richard Piner, and Rodney S. Ruoff: Ultrathin Graphite Foam: A Three-Dimensional Conductive Network for Battery Electrodes, In: Nano Let- ters ASAP, April 23, 2012, DOI:10.1021/nl300528p:
http://dx.doi.org/10.1021/nl300528p
Researchers at Department of Mechanical Engi- neering and the Materials Science and Enginee- ring Program, The University of Texas at Austin (US), report in Nano Letters the use of free-stan- ding, lightweight, and highly conductive ultrathin graphite foam (UGF), loaded with lithium iron phosphate (LFP), as a cathode in a lithium ion bat- tery. At a high charge/discharge current density of 1280 mA g–1
on UGF was 70 mAh g–1
, the specific capacity of the LFP loaded , while LFP loaded on Al
foil failed. Accounting for the total mass of the elec- trode, the maximum specific capacity of the UGF/ LFP cathode was 23% higher than that of the Al/ LFP cathode and 170% higher than that of the Ni- foam/LFP cathode. Using UGF, both a higher rate capability and specific capacity can be achieved simultaneously. Moreover, UGF presents excellent electrochemical stability comparing to that of Al and Ni foils. © Nano Letters
Researchers at University of California, USA, University of Bremen, Germany, and Universi- tat Rovira i Virgili, Spain, have developed a novel screening technology that allows large batches of metal-oxide nanomaterials to be assessed quickly, based on their ability to trigger certain bio-logical responses in cells as a result of their semiconduc- tor properties. In a key finding, the research team predicted that metal-oxide nanomaterials and electronically active molecules in the body must have similar electron energy levels – called band- gap energy in the case of the nanomaterial – for this hazardous electron transfer to occur and oxidative damage to result.
Based on this prediction, the researchers screened 24 metal-oxide nanoparticles to determine which were most likely to lead to toxicity under real-life
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85