This page contains a Flash digital edition of a book.
ACCESS CONTROL | POWER SUPPLIES HPMOM5


6 Fused Output Distribution with Fire Panel Interface This multi-output power distribution module converts one non-power limited 12 VDC or 24 VDC voltage input to 6 power limited outputs. Each output can


be used to power magnetic locks, electric strikes, magnetic door holders, etc. Outputs switch together and operate both fail-safe and fail-secure. Activation is through normally open or normally closed supervised input or the polarity reversal from a fire alarm control panel. A Form C dry output relay will enable HVAC shutdown, elevator recall or trigger auxiliary devices. Class 2 current rated at 2.5 A per output. Diagnostic LEDs per circuit. Power and input trigger LEDs. Power fail supervision relay is Form C rated 1 A @ 28 VDC/115 VAC. Dimensions: 5.3" H x 3.5" W x 1" D (13.5 cm H x 8.9 cm W x 2.5 cm D).


_______________________________________________________________________________________________________________ HPACM4


4 Fused Output Distribution with FACP Interface Distributes one 12-24 VAC or VDC input over 4 independently controlled fuse protected outputs.


S-4


Suppressor Kit Provides proper protection against electrical spikes caused by collapsing electrical fields. One suppressor kit is required for every electrical switching device connected through a relay contact on the N-1000-II, N-1000-III, N-1000-IV, NS2 and NS2+ control panels.


_______________________________________________________________________________________________________________


712BNP 12 V, 7 AH Backup Battery 12 V battery for the NetAXS and PRO2200 panels.


_______________________________________________________________________________________________________________


BAT-3 12 V, 4 AH Backup Battery 12 V battery for the N-1000-III, N-1000-IV, NS2, NS+ series of panels.


_______________________________________________________________________________________________________________ BAT-1


TRANSFORMERS/BATTERIES


X-2 12 VAC Transformer Transformer that converts 120 VAC to 12 VAC. 40 VA rating. AC power supply for the following legacy devices: N-501-LB, N-500- LB-B, N-500-PCM, N-1000-II, N-1000-II-X, and C-100-A1.


_______________________________________________________________________________________________________________ X-4


16.5 VAC 50 VA Transformer 16.5 VAC 50 VA plug in transformer. For N-1000-III/IV, NS2, NS2+, NX4S1 and replacement transformer for PS-1-12E.


Also Available:


X4CAN CSA Approved Transformer CSA Approved 16.5 VAC 50 VA plug-in transformer for N-1000-III, N-1000-IV, NS2, NS2+, NX4S1 control panels.


8 V Battery for N-1000-II Replacement 8 V operational battery backup for the N-1000-II control panels. The BAT-1 provides power to maintain full control panel functions during AC power loss (for up to 3 hours).


_______________________________________________________________________________________________________________ BAT-2


Lithium Battery for N-1000 Replacement lithium battery. Provides backup power for memory retention on the N-1000-II control panels.


Call 1-800-323-4576 for more information.


59


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148  |  Page 149  |  Page 150  |  Page 151  |  Page 152  |  Page 153  |  Page 154  |  Page 155  |  Page 156  |  Page 157  |  Page 158  |  Page 159  |  Page 160  |  Page 161  |  Page 162  |  Page 163  |  Page 164  |  Page 165  |  Page 166  |  Page 167  |  Page 168  |  Page 169  |  Page 170  |  Page 171  |  Page 172  |  Page 173  |  Page 174  |  Page 175  |  Page 176  |  Page 177  |  Page 178  |  Page 179  |  Page 180  |  Page 181  |  Page 182  |  Page 183  |  Page 184  |  Page 185  |  Page 186  |  Page 187  |  Page 188