4 Steve Ruddell examines the implications of the new Minimum Energy Performance Standard regulations.


4 Steve Ruddell examine les implications des nouvelles règlementations relatives aux normes minimales en matière de performance énergétique.


4 Steve Ruddell untersucht die Folgen der neuen Minimum Energy Performance Standard- Regeln.


EU energy standards are spur for better design


U


sing higher efficiency motors reduces the costs of the company using them – remember that electricity consumption accounts for around 95 percent of a motor’s life cycle costs.


This means that payback times for these motors are relatively short - two years on average when compared to older low efficiency motors. Yet, despite the apparent economic advantages


of high efficiency motors, an Economist Intelligence Unit survey commissioned by ABB showed that it requires action by policy makers to ensure widespread use of energy efficient equipment. ABB welcomes the advent of the EU MEPS


(Minimum Energy Performance Standard) regulations, as a spur to companies to improve their use of electrical energy. The regulations require that all motors covered by EU MEPS to be placed on the European market after 16th June 2011 must achieve a minimum International Efficiency standard level 2 (IE2). Although the regulation covers only the European market, ABB will not offer, sell or deliver IE1 CE marked products in any markets across the globe from 16th June 2011. The MEPS requirements cover most two, four


and six pole motors in the power range 0.75 to 375kW for alternating current (AC) power supply frequencies of 50 and 60Hz. The International Energy Agency (IEA)


estimates that it is possible to cost-effectively save 20 to 30 per cent of all power consumed by electric motors using existing technologies such as high efficiency motors and drives. This saving corresponds to 10 to 15 per cent of all global electricity consumption. This encouragement can only be a bonus for design engineers seeking to improve the overall energy efficiency of engineered systems. These efforts are backed up by ABB’s motor development and the


company recently introduced a new technology that raises the efficiency of electric motors by up to 40 per cent. Based on a revolutionary new rotor design, using synchronous reluctance technology, the new motor is robust and has practically no losses. The motor is offered as a complete package together with a frequency converter and dedicated software. The high efficiency package meets the latest


most stringent efficiency level specified by the IEC, class IE4, super premium efficiency. For customers, this means 40 per cent less energy losses than a conventional motor. The motor and drive package is designed


specifically for variable-speed drive (VSD) operation, leading to further energy savings. Thanks to these savings the pay-back time of this package is very short, in many cases less than two years. The second package, high output, is configured


for maximum output. This motor-drive package offers a power density up to 40 per cent higher than in a conventional induction motor. As a result the motor size can be up to two frame sizes smaller than a conventional induction motor, an important benefit for machine builders who often work with stringent space restrictions. Customers who buy this package get the high power density of an equivalent permanent magnet motor with the robustness of an asynchronous squirrel-cage motor. Because the rotor runs cooler than other


technologies, the bearings also run much cooler, making the motor much more reliable. With bearing failure accounting for around 70 per cent of unplanned motor outages, customers will appreciate the longer greasing intervals and higher reliability offered by the new motor and drive packages. l


Steve Ruddell, Global Head of Marketing - Motors & Generators, ABB Limited, Daresbury, Warrington, Cheshire, UK. www.abb.co.uk/energy


“The regulations require that all motors covered by EU MEPS to be placed on the European market after 16th June 2011 must achieve a minimum International Efficiency standard level 2 (IE2).”


Steve Ruddell,


Global Head of Marketing – Motors & Generators, ABB Limited.


10 www.engineerlive.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68