SELF-STUDY SERIES Sponsored by
References
1. Association for the Advancement of Medical Instrumenta- tion. (2020). ANSI/AAMI ST79: 2017. Comprehensive guide to steam sterilization and sterility assurance in healthcare facilities. Arlington, VA: Association for the Advancement of Medical Instrumentation.
2. International Association of Central Service Materiel Management (IAHCSMM). (2016). Central Service Technical Manual, 8th Edition, International Association of Central Service Materiel Management (IAHCSMM), Chicago, IL.
Chasity Seymour is a Clinical Educa- tion Specialist with more than 15 years of operating room, ster- ile processing, educa- tion, management and operational experience in healthcare. She has authored several pub- lished articles and has
been a conference and webinar presenter on various SPD and endoscopy topics. Chas- ity is triple-certifi ed through HSPA with a CHL, CRCST, and CIS in Sterile Process- ing, and is a Certifi ed Surgical Technologist and an Advanced GI Technical Specialist through SGNA. She is an active member of AAMI, AORN, APIC, HSPA, AST, AND SGNA. She holds a Bachelor of Science in Healthcare Management from Texas Tech University Health Science Center.
Pamela Carter is a Senior Clinical Educa- tion Specialist and perioperative registered nurse with more than 27 years of experience. She also holds CNOR, AGTS, CRCST, CER and ASQ- CQIA certifi cations. She has supported a variety of specialties, serving in
both clinical and administrative roles in nursing management, perioperative lead- ership, and sterile processing education. She has written articles for Healthcare Purchasing News (HPN), HSPA Process Magazine, and AORN’s PeriOperative Nursing Clinic. She is an active member of AAMI, AORN, APIC, ASCA, ASQ, HSPA, and SGNA. Pamela holds a Bachelor of Science Degree in Nursing from George Mason University, Fairfax VA, and is pursuing a master’s in nursing/healthcare administration.
CONTINUING EDUCATION TEST • MAY 2022
Ugh! Another wet pack. What’s a technician to do? Circle the one correct answer:
1. ANSI/AAMI ST79 considers residual moisture to be a wet pack when it is: A. On the inside of a sterile package B. Only on the outside of the sterile package C. On the inside or outside of a sterile package D. None of the above
2. Why is residual moisture a problem for steam sterilized items? A. It damages sterilization pouches B. It discolors the instruments C. It creates a pathway for microorganisms D. It’s okay to have residual moisture
3. Which types of factors contribute to wet packs? A. Operational factors B. Functional factors C. Delayed reprocessing factors D. Staffi ng factors
4. Which is an example of an operational factor? A. The temperature and humidity of the SPD B. The results of a Bowie Dick test C. The quality of the steam D. The preparation and loading of instruments into trays
5. What should be inspected and cleaned daily to prevent wet packs? A. Sterilizer safety valve B. Sterilizer racks and loading cars C. Sterilizer chamber drain D. Sterilizer chamber controls
6. Nonwoven, synthetic wraps should be used to line your sterilizer shelves. A. True B. False
7. What type of tray should be used to assemble instrument sets? A. Solid bottom and sides B. Solid bottom and mesh sides C. Mesh or perforated bottom D. Tray with a lid
8. Where should a linen pack be placed within a mixed load? A. The top shelf B. Under rigid container systems C. Between wrapped trays and rigid container systems
D. On the bottom shelf
9. Where should a hot sterilizer cart go for cool- ing? A. Equipment corridor B. Beneath the air conditioning vent C. Low traffi c area D. Sterile storage
10. What happens when a hot steam sterilized item is placed on a solid work surface? A. Condensation B. Slower cooling C. Drying D. Nothing happens
Request for Scoring I have enclosed the scoring fee of $10 for EACH test taken — Payable to Healthcare Purchasing News. We regret that no refunds can be given. (It is not neccessary to submit multiple tests separately.)
Detach exam and return to: Continuing Education Division Healthcare Purchasing News 2477 Stickney Point Road, Suite 315B Sarasota, FL 34231
PH: 941-927-9345 Fax: 941-927-9588
The approval number for this lesson is STERIS-HPN 220404.
Please print or type. Return this page only. Name Title
Hospital Name Mailing Address Apt/Suite
You can now read and take the test online in our new Education Hub:
educationhub.hpnonline.com
City, State, Zip Daytime Phone Email
hpnonline.com • HEALTHCARE PURCHASING NEWS • May 2022 29
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46