PHAM NEWS | NOVEMBER 2024 HeatPumps
Microbore can be a good match
Mitsubishi Electric has issued a white paper that challenges the long-held belief that air source heat pumps and microbore pipework are incompatible. Product marketing manager Joanna Crown outlines the report’s fi ndings.
moving away from gas boilers. Currently, more than 80% of UK households rely on gas, making the shift to renewable heating technologies, such as heat pumps, a critical part of the solution to reach net zero. However, concerns about retrofi tting costs and misinformation about heat pump technology have slowed progress. Microbore pipework is one issue that
A
has been clouded by misinformation, often causing hesitation over its suitability for integration with heat pump technology. It is characterised by diameters of less than 15mm, and this has traditionally been deemed incompatible with heat pumps. However, our fi ndings challenge this notion, showing that with appropriate design and calculations, heat pumps can be retrofi tted into existing microbore systems. Consider non-condensing boilers, which
operate at higher fl ow temperatures and ΔT (Delta T, the diff erence between fl ow and return temperatures), while air source heat pumps typically operate at lower temperatures and smaller ΔT, which could impact the eff ectiveness of microbore systems. So, pipe sizing is a key issue for successful ASHP installation, and it’s one that can have a signifi cant impact on residential heat pump retrofi t projects. With this in mind, we conducted a study
on the compatibility of microbore pipework with our Ecodan range of air source heat pumps, aiming to determine whether the two systems can work eff ectively together. The key question was whether Ecodan heat pumps can match the operating conditions of microbore systems and what could otherwise be done to achieve compatibility.
The fi ndings The outcome of the study is that, with the correct design and installation, Ecodan heat pumps can be integrated with existing microbore systems. This can be achieved by matching operating conditions of the heat pump with those of the existing heat distribution system (e.g. pipes and emitters), particularly in terms of fl ow temperature and ΔT. However, it is crucial to assess its
suitability based on specifi c heating requirements. Factors such as fl ow rate, heat load, and compliance with CIBSE guidelines, including pressure drop and fl ow velocity limitations of 350 Pa/m and 1m/s, respectively, should be carefully considered to ensure optimal performance and effi ciency.
s the UK pushes towards its legally binding net zero target by 2050, one of the greatest challenges is to decarbonise home heating by
The Mitsubishi Electric Guide to
Residential Air Source Heat Pumps and Microbore Pipework
ANTI-FREEZE VALVE SPACE-SAVING SOLUTION WITH SWIVEL CONNECTIONS
INTA ZERO ANTI-FREEZE VALVES HAVE BEEN SPECIFICALLY DESIGNED
Guide
ecodan.co.uk
TO QUICKLY AND ACCURATELY REACT TO THE WATER TEMPERATURE IN THE HEAT PUMP CIRCUIT AND DO NOT
NEED THE INFLUENCE OF THE AMBIENT TEMPERATURE TO OPERATE.
Key fi ndings in the white paper include
recommendations for installers. It also highlights a case study from an installer who successfully retrofi tted a heat pump with microbore pipework, emphasising the importance of proper design and calculations to ensure cost-eff ective and effi cient installations.
Good guidance This research has highlighted a set of guidance recommendations for installers working with microbore systems and ASHPs for retrofi t projects: 1 . Match existing heating system
operating conditions (e.g. fl ow and return temperature, fl ow rate, ΔT) to minimise remedial works. 2. Consider the suitability of existing
heat emitters if existing heating system operating conditions cannot be matched. Radiators may need to be replaced and/or added if the fl ow rate is decreased to suit existing pipe size. 3. Consider the use of hydraulic
separation if existing heating system operating conditions cannot be matched. For example, a low loss header could be introduced to balance ASHP and heating system fl ow rates. 4. Do not use antifreeze fl uid. Instead,
apply an alternative method of freeze protection. For example, a ‘freeze stat function’ is available on Ecodan controls. 5. Ensure the condition of the microbore
pipework is suitable by checking for damage, leaks or blockages. Ensure that the ASHP operation requirements (e.g. fl ow rate and minimum space heating circuit volume) are satisfi ed.
To read ‘The Mitsubishi Electric Guide to Residential Air Source Heat Pumps and Microbore Pipework’, use the link below.
◼
phamnews.co.uk/1124/38
Intatec Limited Airfield Industrial Estate, Hixon, Staffordshire ST18 0PF t. 01889 272180 e.
sales@intatec.co.uk www.intatec.co.uk
Proud to be a leading British Brand
The Inta Zero has a Nickel & PTFE coated operating piston which provides an almost frictionless operation
Where space is restricted we’ve developed the Inta Zero Anti-Freeze valve with swivel
connections to allow fitting directly onto the flow and return of the heat pump. The addition of the Zero Guard allows the anti-freeze valves to be installed
in parallel without the need to offset as the guard will protect the anti-vacuum valve of the Inta Zero installed on the return.
PREVENTING BREAKDOWNS AND COSTLY DAMAGE.
The only Anti-Freeze Valve with an optional patented protective debris shield
Inta Zero will discharge only when the system
temperature drops to 3°C. Inta Zero isn’t affected by ambient temperature
The patent pending anti- drip outlet prevents water droplets freezing and blocking the outlet in the event of a system discharge
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48