Feature: Components


Figure 4: ECB tripping delay depending on current slow tripping characteristic


feature can be used, which provides 5-6 times the nominal current for a few milliseconds. Alternatively, the power supply must be oversized, which means using a higher power class. Both solutions have their disadvantages: users may pay for functions they do not need, and a larger power supply requires more space in the system. Even with a perfectly matched power supply to the MCBs, it may happen that the short-circuit current is not suffi cient to trip the circuit breaker – for example, if the total resistance of the short- circuit path is too high. If you want to combine a power supply with an electronic circuit


breaker, only the available maximum output current of the power supply is relevant for the decision. For an ECB of the PISA-M type, we recommend a power supply with output of at least 90W. T e selection is thus much more fl exible. T e 480W DIN rail power supply CP20.248 features easy fuse


breaking with three times the nominal current for 12ms. T is means that choosing the right circuit breaker requires


a precise understanding of the application and careful system planning. All this takes time, engineering resources and, ultimately, money. With every small change in the application, it must be


determined again whether the circuit breakers still provide suffi cient protection for the existing loads. With an electronic circuit breaker, this eff ort can be signifi cantly reduced. In addition to wiring, only the confi guration of the output currents needs to be done. Our PISA modules with integrated eFuses protect loads


by reliably tripping aff ected channels, regardless of the load, temperature, power supply, or total resistance of the short-circuit path.


Figure 5: The tripping current of MCBs is always specifi ed as AC in the datasheet and must be multiplied by 1.41 to convert to DC values; this table shows the AC current and the corrected DC current


www.electronicsworld.co.uk September 2025 33


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44