Automotive
Contrinex fiber-optic sensors ensure fast and safe automotive brake cable production D
uring manufacture of automotive parking-brake cable, multiple strands of steel wire are twisted
together, forming a single cable. After twisting, the cable passes to the next process in an unsupported, continuous length. Occasionally, the cable breaks, compromising safety and damaging equipment. Although the cable’s exact path is unpredictable, a multi-beam fibre- optic sensor detects its presence, interrupting the process if it breaks.
Customer application During production of automotive parking- brake cable in a Portuguese factory, strands of steel wire are twisted together, forming a single cable with a nominal diameter of 3mm (0.1in). The process operates continuously, and twisted cable passes between successive work-stations in an unbroken length. Between operations, the cable is largely unsupported, assuming the form of a suspended catenary. Occasionally, a manufacturing defect causes the cable to break. In this event, safety is compromised and, unless processing is halted, machine breakdowns
occur. A sensor system must detect the presence of the cable as it passes from one operation to the next, interrupting the process if it breaks.
Because the cable is unsupported, its path is unpredictable and its exact position at any time, particularly in the vertical plane, is unknown. The sensor system must detect the presence of the cable reliably at any point within an envelope 90mm (3.5in) high and 20mm (0.75in) wide.
Customer solution
A Contrinex photoelectric sensor system, comprising a DIN-rail-mounted fibre-optic amplifier coupled with a multi-beam diffuse sensing head, provides an optimal solution for this application. With maximum switching frequencies of up to 4000 Hz and sensing distances of up to 150mm (6in), multi-beam fibre-optic sensors are ideal for detecting fast-moving targets. The PBTP construction of the sensing head ensures excellent mechanical protection in the production environment. The 28mm-wide sensing face of the multi-beam sensor detects targets across its entire width, providing a detection envelope that comfortably accommodates the customer’s 90mm x 20mm requirement. Initial set-up is accomplished by means of a manual teach-in function and integral signal-strength LCD, following which the system operates without manual intervention. A 2m-long fibre cable allows remote mounting of the fiber-optic amplifier; connection to the customer’s control system is via an industry-standard PNP interface and an integral M8 cable connector, allowing easy removal and replacement when necessary.
The system tolerates high ambient-light conditions and detection of a broken cable is both highly reliable and immediate. If the cable breaks, the system interrupts the process and sounds an alarm, alerting the operator. Downtime arising from broken cables has been eliminated since the system has been operational.
Key advantages include: • Rapid, reliable detection of a small, fast- moving target with an erratic path
34 February 2020 Components in Electronics
• Elimination of downtime arising from broken cables • Highly cost-effective solution to a potentially costly problem • System switching frequency of up to 4000 Hz • Exceptionally reliable detection across a 90mm x 20mm envelope • Diffuse detector with simple set-up and teach-in function
PLUSAx.co.uk www.cieonline.co.uk
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76