SUPPLEMENT FEATURE ELECTRICAL SAFETY Electrical safety assured with baying system In low voltage switchgear, all the metal Benefits at a glance


Automatic potential equalisation with the Rittal TS 8 baying system offers the following benefits:


• Saves mounting as many as seven earthing straps


• Simplifies the assembly and


disassembly of all the panels


S


afety and security are two high priorities for installers and users of


electrical switchgear. To prevent personal injury or property damage as a result of issues such as fault currents (short circuits), a number of industry standards and regulations have to be followed. These also cover the potential equalisation between all the metallic parts of an enclosure. The TS 8 baying system from Rittal is a great example of how safety can be built-in through automatic potential equalisation without necessarily having to separately earth each individual panel. The earthing of metallic parts on electrical systems for safety reasons is prescribed virtually everywhere. This applies to all electrical equipment and units – from simple lamps to low voltage distribution systems. The reason is quite clear: if a problem occurs (for example, an enclosure becomes live) it has the potential to cause serious harm.


frame and enclosure parts endangered by stray voltage have to be earthed.


ATTACHING THE EARTHING STRAPS To this end, earthing straps of copper wire are usually provided. These are flexible and therefore can safely contact moving parts (such as doors) to the enclosure. In enclosures, earthing straps typically also have to be connected to the frames, the side panels, the enclosure roof and any other panels. Once all the earthing straps have been correctly fitted, there is an equalisation of potential, and all the enclosure component can be earthed via the protective conductor of the voltage supply. The earthing straps have to be attached to enclosures by hand during their assembly, creating the potential for human error. Should a strap be forgotten, the finished switchgear will still be able to function despite the danger it might pose to people in the event of a fault.


POTENTIAL EQUALISATION EVEN WITHOUT AN EARTHING STRIP To help limit this risk, Rittal has developed an effective solution with the TS 8 bayed enclosure system. During the assembly phase, the side panels, enclosure roof, rear panel and gland plates are automatically connected to the frame conductively. This means potential equalisation can be achieved without necessarily having to connect these parts with earthing straps (although the final decision as to


whether to leave earthing strips out completely is up to the user). The solution is implemented using


special claws or washers which press through the electrically non-conductive surface coating of the panels during assem-bly, to achieve a reliable contact. It means that all the flat panels are electrically connected to the frame, so that – in many applications – earthing straps are no longer needed. Instead, the earthing strap only needs to be attached to the enclosure door. The contact resistance between the panels and the enclosure frame is less than 0.1Ω, the value demanded by the DIN EN 62208 empty enclosures standard.


SIMPLIFIED INSTALLATION AND GREATER SAFETY This automatic potential equalisation reduces the amount of material needed and enables easier assembly, simply because the time-consuming attachment of up to seven earthing straps per enclosure is no longer necessary. What’s more, it is also easier to disassemble and re-assemble individual panels because the earthing straps do not have to be removed and re-attached each time. Users must consider, during a risk assessment, whether the design measure of automatic potential compensation is sufficient or whether separate earthing straps are needed to meet the technical safety requirements.


Rittal www.rittal.co.uk www.friedhelm-loh-group.com


Enclosures from the smallest to the largest.


ENCLOSURES POWER DISTRIBUTION CLIMATE CONTROL


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72