TECHNOLOGY IN ACTION ADVERTORIALS
ADVERTORIALS
protects 24V applications
DC emergency power supply for industrial, medical and security technology Plug&Play for quick and easy installation
The UPSI-2412DP2 has an integrated USB interface for connection to an IPC system and is recognized directly as a UPS by the operating system – without additional driver or software installation.
Software ‘UPSGen2 Configuration’ – Extended functionality and real-time monitoring for setting and parameterizing the DC UPS system as well as real-time monitoring. The UPS and energy storage status displays include all relevant voltages, currents as well as temperature, state of charge (SOC), run times and cycles. Pre-settable parameters include load sensor (mA), shutdown delay, maximum backup time, minimum charge capacity before system start, timer function and restart delay. With the set values, stand-alone operation is then possible.
Timer function for controlled system shutdown according to time specification
The new DC UPS UPSI-2412DP2 from Bicker Elektronik, Donauwoerth/ Germany, reliably protects safety-relevant 24VDC applications against system failure and data loss. Fast-charging and absolutely maintenance- free Supercaps (supercapacitors / EDLC) are used for buffering the DC supply voltage. Due to their high cycle stability, supercapacitors have a particularly long service life and are maintenance-free. For the supplied application, this means an increase in long-term availability with simultaneous minimization of the maintenance effort. The compact all-in- one solution in a robust DIN rail housing is ideally suited for long-term use in control cabinet applications and decentralized solutions for protecting embedded IPCs, controllers, motors, sensors, measurement, control and safety technology, and many more.
Supercaps – short charging times, long service life Unlike batteries, which store energy via a chemical reaction, Supercaps are based on electrophysical principles and are charged and ready for use within a very short time. Under comparable operating conditions, supercapacitors have a service life up to 10 times longer than classic lead- acid batteries. The powerful DC UPS module UPSI-2412DP2 with integrated Supercap energy storage (13.5 kJ) allows fanless 24/7 continuous operation in the extended operating temperature range from -20 to +70°C. Thus, the UPSI-2412DP2 ensures highest reliability and safety for demanding and laboratory technology, renewable energies, process technology, infrastructure, surveillance, safety, vision and inspection, among others.
Intelligent input current detection
The implemented PowerSharing function of the UPSI-2412DP2 ensures on the input side that the input power is kept constant and distributed to load and Supercap charger (max. 4.5A charging current) in an appropriately charger and vice versa. Thus, an upstream AC/DC power supply can be optimally dimensioned.
24VDC emergency power supply with regulated output voltage In normal operation, the UPSI-2412DP2 forwards the input voltage directly to the output, charges the integrated LiFePO4 battery pack in parallel and monitors all relevant parameters, currents and voltages. In the event of voltage dips or a power failure, a MOSFET disconnects the input within a few microseconds and the connected load is supplied with power from the energy storage without interruption. In backup mode, the UPSI-2412DP2 provides a constantly regulated DC output voltage.
The new parameter “Shut Down OS in” can also be used to set the time before the computer system is shut down and switched off in the event of a power failure. This means that, in addition to your own operating system settings via the state of charge of the energy storage (“Shut Down OS at shutdown in UPS backup mode.
Minimum load detection the DC load in UPS battery operation can be set and monitored via the load sensor. If the load at the output of the UPSI-2412DP2 falls below this limit value, the integrated LiFePO4 battery is automatically disconnected from the charging and control unit after 10 seconds, so that no unnecessary and creeping discharge can take place. In addition, the UPSI-2412DP2 can also
Potential-free relay contact for PowerFail
The functionality and behavior of the 2-pin relay connection in the event of closed, the resistance between the two pins is 0 ohms, otherwise the
Shutdown & Reboot function for IPC systems voltage via the integrated interface, so that a controlled shutdown of the computer system is initiated and valuable data is saved. After the supply voltage returns, the integrated reboot function automatically restarts the supplied industrial PC without the need for complex on-site intervention, e.g. locations.
Quality, safety and reliability – Made in Germany With its own development and battery production, Bicker Elektronik guarantees the highest quality and safety for all DC UPS products and supply specialists at Bicker Elektronik. On request, the development offer extensive laboratory and measurement services for complete customer systems.
Bicker Elektronik
https://www.bicker.de/
FEBRUARY 2024 | PROCESS
JANUARY 2021 | PROCESS & CONTROL 49
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58