POWER DEVICES Basics: Parallel or series operation o
A single power supply is most of the time sufficient in applications connected to an AC power source. However, there are sometimes additional boundaries set to fulfill, either higher power needs, system reliability, or even mechanical constraints. Here Alexander Mezin, senior field application engineer EMEA at SL Power Electronics explains the typical scenarios of connecting more than one power supply in the same system and the reasons behind it.
T
he connection of two or more power supplies for redundancy is important in critical applications, where the power source fails
cannot be tolerated. The current sharing circuit or, load sharing circuit, is the ability to manage the output current evenly across all active power supplies to greatly reduce stresses on each power supply and allow them to run cooler, which results in higher reliability of the active power supplies. A redundant sharing is the control of the power supplies internally
or externally by switching only the desired number of the power supplies in parallel at the same time. In case of a power failure, the control circuit will automatically switch to another redundant power supply for continuous power delivery. Active redundant configuration allows it to keep some of the connected power supplies in parallel not loaded and so the critical components are not stressed. Such a system approach extends the lifetime of the spare power supplies. A typical selection of the power supplies for redundancy requires
choosing the same type of power supplies connected in parallel to ensure identical operation no matter which unit will be connected to the load. Although there may be more than one way to wire load sharing
with parallel power supplies, the star wiring method is typically the one most recommended. Demonstrated below are the three typical star wiring schemes that provide options for any desired level of redundancy: This first method in figure 1 below (left) demonstrates a basic star-
wiring scheme that offers a basic level of redundancy without the inclusion of extra components that are not strictly necessary for a load-sharing function. However, many safety-critical systems demand reliability that
evolves an advanced redundancy that requires additional components to this load share wiring scheme as shown in figure 1 (middle).
SL Power NGB Although OR-ing diodes are a successful and redundant method in
their simplicity, they may be neglected for their power losses impact. This level of redundancy is still achievable without the impact of such power losses as figure 1 (right) exemplifies. This elaborate scheme consists of the same basic OR-ing star-wiring method, however it is considerably more efficient. It demonstrates the introduction of a relevant OR-ing system with the use of MOSFETs driven by a compatible integrated circuit controller.
Higher current (parallel operation) The reasons for the connection of several power supplies in parallel instead of using higher power units can be for example modular configurations or a variety of applications in a design house with an extended wider power range, mechanical limitations, or even lack of products in the market with the desired specification. A common example in modular applications is when the system designer adds more and more power supplies in parallel as the system building blocks are added. In a wide variety of scenarios, the purchasing team might prefer to have one single power supply on their bill of materials in simple designs and stacked power supplies in parallel from the same type in more powerful ones. The selection requirements of power supplies in parallel operation
are similar to those for redundancy, but the control function differs. It is obvious, in this type of application, a single unit is not sufficient to provide desired power needs, so two or more power supplies in parallel are expected to be always loaded. The control circuit responsibility shifts here to balancing the load sharing among the connected power supplies equally as possible. The balancing circuitry implementation can be achieved both,
internally in the power supply or also with external control units. An example for internal control implementation would be an additional load-sharing IC such as UCC29002 from TI. Power supplies in parallel
Figure 1: Redundant operation, basic star wiring options 22 DECEMBER/JANUARY 2022 | ELECTRONICS TODAY
Figure 2: Parallel operation, internal (left) and external (right) current share control
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42