VENTILATION BSEE


INVESTING IN AIR QUALITY Affordable, effective ventilation


Poor indoor air quality has known links to allergies, asthma, lung cancer, chronic obstrucve pulmonary disease, cardiovascular disease and even demena. For the building, surface condensaon formed from poor venlaon can lead to significant structural problems and costly redecorang. David Treharne, senior engineer at Domus Venlaon, discusses


managing indoor air quality


Whilst outdoor air pollution is largely out of your hands, you can take steps that will improve indoor air quality. The quality of air in a property is, according to Professor Alastair Lewis, National Centre for Atmospheric Science, University of York, “largely a consequence of a series of specific occupant actions coupled to the building air exchange rate, both factors over which individuals have a substantial degree of autonomy and control.


I


In most locations (away from busy roads), outdoor air is likely cleaner than indoor for most classes of air pollution. In such circumstances reducing the indoor emissions of pollutants, for example by changing patterns of discretionary combustion and chemical consumption, may lead to direct reductions in exposure, as can actions that increase ventilation.”


In light commercial settings, kitchens and bathrooms are usually the most affected areas, but buildings with bin stores, communal areas and even meeting rooms can also be problematic.


Extract fans: the simple soluon


Mechanical extract fans designed for the commercial market can be effective here, depending on the size of the area and the level of contaminants and moisture in the air. Getting the balance between fan performance and noise levels is important so look for a fan with a high efficiency impeller and external rotor motor that also operates quietly to avoid disturbing occupants; Domus Ventilation D SERIES fans operate up to 530l/s or 1908m3/hr and with sound levels as low as 31dBA.


Minimise energy consumption by opting for fans with an economy speed setting and also look for those that can be used with a range of sensors such as PIR, humidity and a run- on timer so you are not restricted to just one option. Where you have a number of fans in place, a speed controller that connects to multiple fans is very useful.


Although harder to find, fans are available – including the Domus Ventilation D SERIES, that feature supply and extract technology so not only can you use the fan to extract stale air but also to feed in air from outside.


Mechanical Extract Venlaon: the next step up


Whilst motorised extractor fans are ideal for dealing with ventilation in well-defined areas (mostly single rooms), there are many occasions where a more sophisticated and powerful solution is required, especially where there are multiple rooms in need of extract ventilation and the air change requirement is more onerous, e.g. in shared accommodation such as student flats or care homes. Here, a Mechanical Extract Ventilation (MEV) system should be considered.


uDomus Ventilation D SERIES fans operate up to 530l/s or 1908m3 levels as low as 31dBA


/hr and with sound


An MEV system actively extracts air from ‘wet rooms’ (kitchens, bathrooms, utility spaces) via ducting to a central ventilation unit which further ducts to an exhaust point. The systems are typically dual speed, providing low speed continuous trickle ventilation and high-speed boost flow. Replacement fresh air is drawn into the property via background ventilators located in the habitable rooms and through air leakage.


MEV systems are most suitable for new properties although can be retrofitted as long as there is access in ceiling voids for duct runs.


MEV systems provide excellent ventilation, are very easy to use (mostly a fit and forget scenario as they don’t have filters that need changing), are cost-effective in terms of capital outlay and operating costs, and are straight forward to install. On the installation side, MEV systems require minimal ducting and do not require each room’s outer wall to be drilled for an extract fan - even more handy if wet rooms don’t have access to an outer wall.


There are a wide range of MEV units in the marketplace to choose from. When looking at suitable units, firstly ensure it has been designed for the commercial market, as residential MEV units will not be powerful enough. Domus Ventilation’s CMX-S, for example, can extract up to 120l/s. Consider where the MEV unit is going. Generally, they are fitted in lofts or cupboards, but if that isn’t an option then opt for a smaller unit that can fit in a ceiling void, such as Domus Ventilation’s CMX-S at just 125mm deep. Also look for units with a versatile design that allow them to be installed horizontally or vertically, ensuring ease of installation in limited or awkward spaces.


As is the case with extract fans, you want to ensure maximum performance with minimal noise. To achieve this the MEV unit needs a good quality electronically commutated (EC) motor plus, ideally, direct connection to the ducting (without the need for adaptors) which maximises airflow performance as well as significantly reduces system noise. A low specific fan power (SFP) is also ideal to keep energy usage down to a minimum; Domus Ventilation’s CMX-S has an SFP of 0.24W(l/s), well below the 2010 Building Regulations Part L threshold.


Whilst MEV systems operate continuously, those that have a high-speed boost flow come with a variety of control options for you to consider with the most common being a straightforward switch; a combined PIR sensor and timer which detects the presence of someone; a combined humidity sensor and timer; and the increasingly popular integral humidistat that identifies changes in humidity and automatically adjusts the air flow of the unit accordingly.


Invest in venlaon


uWhilst outdoor air pollution is largely out of your hands, you can take steps that will improve indoor air quality, as in this illustration of an office, equipped with Domus ventllation


VISIT OUR WEBSITE: www.bsee.co.uk


A stuffy room is the direct effect of poor ventilation; it’s uncomfortable to be in and can affect the health of the occupants. Opening a window simply isn’t good enough, especially in a commercial setting. Mechanical ventilation is necessary if you are to maintain a healthy, breathable atmosphere, but it doesn’t have to cost the earth.


www.domusventilation.co.uk BUILDING SERVICES & ENVIRONMENTAL ENGINEER DECEMBER 2018 29


ndoor air quality is determined by a number of factors, including the quality of the outdoor air, indoor pollutant sources (e.g. cleaning equipment), the activities within the property and the physical features of the building.


uThere are a wide range of MEV units on the market to choose from. When looking at suitable units, firstly ensure it has been designed for the commercial market, as residenal MEV units will not be powerful enough





MEV systems


provide excellent venlaon, are very easy to use (mostly a fit and forget scenario as they don’t have filters that need changing), are costeecve in terms of capital outlay and operang costs and are straight forward to install.





Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50