AheAd of the Curve: titAn enterprises CelebrAtes over 40 YeArs of innovAtion
primary focus for the manufacturing industry and Titan’s design and engineering expertise has been fundamental to the company’s success. Titan’s most popular flowmeters have been
T
born out of collaborations and investing in its R&D capacity. “We have a proud history of working with some of industry’s key players, such as Coca Cola Enterprises Ltd, RS Components and Vianet, to industry specialists like Formula 1, the Virgin Atlantic Challenger II team, Paxman Coolers, Stored Crop Conservation and Green Fuels,” Trevor Forster, managing director of Titan Enterprises, says. “Our USP is our flexibility, adaptability and ability to work with customers to understand their applications and find workable solutions.” R&D projects could be anything from testing
new materials for longer life, chemical inertness, robustness, testing under high pressure or temperature or software development. Design improvements and technological advancements are focused around finding innovative solutions for our OEM customers, pushing the boundaries of both the physical properties and performance of the products.
itan Enterprises has been manufacturing optimised liquid flow measurement solutions for more than 40 years. In a constantly fluid economy, continuous innovation is a
Taking Titan’s Atrato ultrasonic flowmeter
product design understanding, the company has pushed both electronics and physical design to improve the overall performance window. From the company’s extensive pioneering work with a USA medical company to produce a disposable ultrasonic flowmeter that measures the volume of liquid manually injected into a patient, to recently launching a new software interface for the Atrato product range. Titan’s Process Atrato ultrasonic flowmeter,
designed to IP65 standards, is built to address the more challenging industrial process and control environments. Rated for use up to 65°C and 20 bar pressure, the compact Process Atrato is available in four models operating over flow ranges from 2ml/min to 15litres/min, featuring an accuracy of ±1% over the whole flow range. Each Process Atrato is calibrated with a pre-set ‘K’ factor so all meters of the same flow range are fully interchangeable simplifying assembly and set-up procedures for OEM manufacturers looking to integrate the flowmeter into their process and control set-up. The advanced Atrato signal processing system
permits flow measurement across the whole Reynolds number range allowing both viscous and non-viscous products to be metered anywhere. Durably constructed from 316 stainless steel and
PEEK, and incorporating Titan’s proprietary ultrasonic flowmeter technology, the Process Atrato offers reduced cost of ownership compared to existing flow measurement devices used in the process and control market. Further information is available at
www.flowmeters.co.uk/process-atrato-process- control-ultrasonic-flowmeter/ To read the full article, please visit
www.flowmeters.co.uk/ahead-of-the-curve/
Titan Enterprises
www.flowmeters.co.uk T: 01935 812790 E:
sales@flowmeters.co.uk
versAtile digitAl pressure MeAsureMent…
or signal conditioning instrumentation. The transducer is powered by the computer’s USB port through the 2m lead which is supplied as standard, and connected directly to the pressure source though a variety of thread options available to your specification. Live pressure measurement readouts are then
E
displayed on the screen of your laptop or PC with the use of the FREE ESI-USB downloadable software. Up to 16 pressure inputs can be connected and monitored at the same time. Whether you are looking to perform test and calibration, spot checks or local, direct monitoring, the GD4200-USB is the convenient solution.
The hardware
Made from a specialist titanium alloy, the USB transducer comes with a variety of thread options and offers excellent chemical compatibility, including use within Hydrogen environments. Capable of measuring up to 5,000 bar in both gauge and absolute pressure reference, what makes the USB truly unique is the use of ESI’s Silicon-on-Sapphire (SOS) sensor technology. SOS combines the insulating and elastic properties of
SI Technology’s Dynamic GD4200-USB digital pressure transducer has been specifically designed to measure, analyse and record pressure data directly to your PC without the need for costly I/O interface boards, separate power supplies
Sapphire to produce a sensor that is durable, and resistive to high overpressures and electromagnetic pulse radiation. This allows the sensor to perform consistently at an accuracy rate of ≤ ±0.15 per cent of span BFSL across a wide temperature range, making it ESI’s most durable and effective sensor on the market.
The SofTware
The ESI-USB software is easily downloadable from ESI’s website using the credentials supplied on purchase. Users may choose between a monitor or graph screen to view pressure data, as well as access configuration details from the calibration screen. Pressure test readings can be downloaded into customised test reports, and users can access features such as leak testing or data markers with ease. The sample rate allows the user to view pressure
data measured with up to 21-bit resolution at selectable speeds up to 1,000 Hz, with a range of pressure units and a fully adjustable scale to choose from. Watch a demo on YouTube (Search GD4200-USB),
or contact the ESI sales team on 01978 262255 or
sales@esi-tec.com for more information.
ESI Technology Limited T: 01978 262255
www.esi-tec.com E:
sales@esi-tec.com
12
www.instrumentationawards.co.uk
IEA Supplement 2022 Instrumentation Monthly
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102