ADVERTORIALS


flow meter for the measurement of pumped, full pipe Wastewater and other solutions, suspensions or aerated liquids including: Raw Sewage, Viscous Liquids, Sludge & Slurries, Solvents, Pulp Stock, Food Products, Lubricating Oils & Crude Oil. It’s a non-contact, non-invasive, Doppler flow meter with the facilities to measure, display, totalise, log and provide control functions from outside the pipe i.e. no need to drain-down systems or cut pipes and easy maintenance with the following benefits: No blocked flow sensors, obstruction to flow, system pressure drop, sensor corrosion or contamination of the liquid being measured. The meter is suitable for pipe sizes from 12.7mm to 4500mm, the enclosure is watertight (IP 66) and it has Intrinsic Safety Barriers for mounting in hazardous locations. A New integral 26 million point data logger is now a standard feature and the meter now supports Industrial Automation Protocols: Modbus RTU via RS485 or HART (field selectable).


THE NEW UF D5500 FIXED CLAMP-ON FLOW METER T


he New UF D5500 from Micronics is a “Best Value” easy to use, non-contact


Micronics u 01628 810456 u www.micronicsflowmeters.com


INTERNAL POWER SUPPLIES FOR INSTRUMENTATION APPLICATIONS


a variety of products and applications. The 36LM range offers


I


a variety of features including protection circuit, high performance, reliability, safety approvals and high efficiency suited for instrumentation projects. Single, Dual and Triple output versions are available with or without isolation. The


36LM range can be used in harsh working environments capable of working in ambient working temperature range of -30°C ~ 70°C (with derating). The 43TAC range has been specifically designed to meet IEC/EN/UL 62368-1 standards,


this range uses high end components to offers exceptional performance with low standby power consumption of 0.025W. The 43TAC has an adjustable output voltage with a low leakage current under 75µA. The 43TAC range is suitable for instrumentation, automation, data and industrial applications.


Ideal Power Ltd u 0845 260 3400 u www.idealpower.co.uk


MINIMISING DOWNTIME, OPTIMISING PLANT EFFICIENCY


sensors/encoders, vibration sensors and associated speed relays. The heavy duty sensors are installed on the end of the shaft or on the belt being monitored. They send an electrical signal proportional to the speed of the shaft/belt to a suitable control unit. The control unit can be a “Rotech” speed relay, a programmable controller, a computer, data logger device or other proprietary control equipment. The alarm level of the control unit is set to just below the normal running speed of the shaft. In the event of the shaft/belt slowing below the set level, the control unit operates and can be connected to give an alarm to the operator and/or shutdown preceding items of plant. Wherever materials are transported or processed by conveyors, elevators, screws, crushers, mixers etc. there are applications for “Rotech” motion sensors/encoders.


T Rotech u 0151 356 2322 u www.rotechsystems.co.uk


he “Rotech” range of monitoring equipment is comprised of a range of motion


deal Power specialise in power supplies for use in


enabling users to quickly determine the solder quality of products; market leading image quality makes it quick and easy to locate and qualify potential defects and make pass/fail judgements. The imaging chain in the


X-RAY FOR PRODUCTION MONITORING A


vailable from Cupio, Explorer One delivers clear x-ray images


Explorer One draws on the Quadra series of tubes with their matched flat panel detectors and supplies, all designed and manufactured at Nordson Dage. This gives 2 micron resolution with, thanks to this imaging chain, a brightness and clarity expected of much larger systems. The Explorer One is reported to be ground-breaking in other ways too. There is no


lead used in the shielding of this system, which helps to protect the environment and greatly reduces the system weight. There is no compromise on safety and the system is fully compliant with world-wide standards.


Cupio u 01962 832654 u www.cupio.co.uk


REMOTE PAPERLESS TEMPERATURE RECORDING ELIMINATES HUMAN ERROR


with a Barcode Scanning Thermometer to deliver enhanced data integrity. TME’s TC Wall Port System is a practical, low cost method of testing inaccessible temperature points compatible with any thermocouple input thermometer – ideal for enclosed pipes and high level water tanks for legionella prevention; also cold stores; freezers; ovens and hazardous storage areas.


T


How does it work? The new double port saves space and reduces costs - integrally wired with two thermocouple fine-wire sensors instead of one. The sensors can be run to separate temperature points up to 20 metres away, such as hot and cold water pipes or multiple cold stores or ovens, and then left in situ with ongoing tests performed by plugging a thermometer into the port for an instant, accurate result.


Enhanced data integrity Eliminate human recording errors by combining TC Wall Ports with TME’s MM7000-2D Barcode Scanning Thermometer with Bluetooth.


TME Thermometers u 01903 700651


70 u www.tmethermometers.com May 2019 Instrumentation Monthly


ME’s NEW Double TC Wall Port for remote testing of two temperature points from one location, can be combined


NEW "INDUSTRY-LEADING" WHITE PAPER "INTERFACE IN THE FIELD"


expert insights, technology comparisons and case studies. Interface or multiphase level measurements exist throughout the oil & gas streams as


C


well as petrochemical. While level measurement technologies have come a long way in effectively measuring liquids and solids, multiphase level measurement continues to be the biggest challenge and opportunity that exists today to which there is no perfect technology. However, experience has shown that process optimization and increased uptime can still be achieved in many separator applications through reliable, best-in- class, level technology.


The white paper covers:


• interface challenges; • case studies in Oil & Gas and Petrochemical;


• comparison of level technologies for interface measurement; and • the future of reliable interface measurement.


Magnetrol u +32 52 45 11 11 u www.magnetrol.com


ontrolling interface is critical to process optimization and uptime. Magnetrol® has just released a new white paper examining interface challenges from the field with

Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82