SHAFT TUNNELING | INTERNATIONAL


the geotechnical information needed to be confirmed. Further geotechnical information obtained during detailed design confirmed the need for pre-sink piles. Genex says the lesson learnt here highlights the


importance of good geotechnical investigation and analysis to make informed decisions on ground treatments and supports. This was a known risk at the Kidston Project and was confirmed and addressed prior to raisebore operations commencing.


PILOT HOLE The pilot hole links the top and bottom of the shaft and ultimately sets the shaft alignment. Ensuring verticality when drilling the pilot hole is of utmost importance. At Kidston, the pilot hole for each shaft was drilled using the rotary vertical drilling system. The pilot hole within the cable shaft encountered


a rogue geotechnical monitoring instrument at depth, which twisted around the drill head and affected the verticality of the hole, and in turn the shaft. This was remedied by removing the pilot hole drill rods, clearing the drill bit, and recommencing pilot hole drilling. The lesson learnt relates to ensuring that the


utilization of state-of-the-art positioning and drilling equipment will provide the greatest chance of shaft


verticality. Genex says that other methods are available but for the Kidston Project, verticality was paramount and would not have been achieved without the use of the rotary vertical drilling system.


REAMING OPERATIONS AND REMOVAL Once the cutter head is in action it is critical to ensure that for safe operation the cuttings are free to fall to the base of the shaft and removed frequently to make sure they don’t block the shaft opening. In previous projects shafts have choked and resulted in the uncontrolled movement of cuttings into the bottom of the shaft, filling the underground works with such force that equipment has been known to be transported up the tunnel drive. The Genex report highlights that good


communication between underground and raise bore teams is critical during reaming operations. The appropriate methodology and safety provisions are also required to facilitate removal of the reamer head at the surface. This minimizes time and cost as opposed to attempting to lower the reamer head to an underground chamber because, at a depth of 250m, the reattachment of drilling strings to lower and then the subsequent removal of these is time-consuming.


KIDSTON PUMPED STORAGE: KEY FACTS


The 250MW Kidston Pumped Storage Hydro Project (K2-Hydro) is a landmark renewable energy project and the centerpiece of the Kidston Clean Energy Hub in Far-North Queensland, Australia. This project is a critical component in Australia’s shift


towards renewable energy, designed to generate, store, and dispatch power during peak demand periods.


Key Features ● Nameplate Capacity: 250MW ● Storage Capacity: 2,000MWh (8 hours of continuous generation)


● Start-Up Time: Less than 30 seconds ● Lifespan: 80 years ● Water Head: max 218m (238 yd) - min 181m (198yd) ● Turbines: 2 reversible turbines (125MW each) ● Upper Reservoir: Wises Pit (52 hectares) ● Lower Reservoir: Eldridge Pit (54 hectares)


The Kidston Pumped Hydro Project is the world’s first to repurpose an abandoned gold mine, utilizing Wises and Eldridge pits as its upper and lower reservoirs. This innovative approach to energy storage taken at the Kidston project reduces capital expenditure by reusing existing mining infrastructure, such as an accommodation camp, airstrip, and water supply systems, resulting in faster construction and lower costs. The Copperfield Dam provides a stable water source for the hydro system via an existing pipeline, further minimizing additional infrastructure needs.


The project is also integrated into the larger Kidston Clean


Energy Hub, which combines large-scale solar, wind energy, and pumped storage hydro. This integration allows for efficient energy generation, storage, and dispatch, providing reliable renewable energy on demand, especially during peak periods. A dedicated transmission line will connect the hub to the National Electricity Market (NEM), enhancing the stability of North Queensland’s grid and providing much- needed system strength. Financially, the project reached contractual close in


April 2021, with construction starting in May 2021. The total construction cost is approximately A$777 million (US$590 million, at 2021 currencies), backed by a robust funding package. A 15-year, A$610 million debt facility was secured from the Northern Australia Infrastructure Facility, alongside a A$47 million grant from the Australian Renewable Energy Agency (ARENA), and an additional A$3 million of subordinated debt from the Clean Energy Finance Corporation. The project is set for completion by 2025. The economic benefits of the project are considerable, with 900 direct jobs created during the construction phase. Additionally, the project will help Queensland meet its Renewable Energy Targets of 70% by 2032 and 80% by 2035, playing a vital role in Australia’s clean energy future. By combining innovation, integration, and economic value, K2-Hydro is a model for future renewable energy developments. The project is being delivered by leading contractors


McConnell Dowell and John Holland, with Entura providing engineering consultancy.


This article was published originally by T&TI’s sister magazine, International Water Power & Dam Construction


Spring 2025 | 51


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61