Standards - Consumer Units and Circuit Protection Devices


Product Standard


Consumer Unit BS EN 61439-3 Main Switch MCB


RCBO SPD RCD


EN/IEC 60947-3 EN/IEC 60898 EN/IEC 61009-1 IEC 61643-11 EN/IEC 61008


Product Enclosure Contactor


Transformer AFDD


Connector Block Standard EN/IEC 61439


EN/IEC 60947, 61095 EN/IEC 61558-2-8


IEC/EN 62606 & IEC/EN 61009-01 EN60947-7-1


Technical • Terminals


Device Switch MCB RCD


Unidirectional RCBO


SPD


Bidirectional RCBO


Capacity mm2


35mm² 25mm² 35mm²


25mm² L in


4-10mm² L/N Out 1.5-6mm² 25mm² L in


4-10mm² L/N Out • Knockouts per face Modules Left Side Right Side


4 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm 6 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm


Base Knockout Qty Top (mm)


2 x ø20mm + 1 x ø32mm 1 x ø20mm + 3 x ø32mm


Bottom (mm) 2 x ø20mm + 1 x ø32mm 1 x ø20mm + 2 x ø32mm + 1 x ø40mm


9 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm 1 x ø20mm + 1 x ø25mm + 3 x ø32mm 1 x ø20mm + 1 x ø25mm + 3 x ø32mm 12 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm 1 x ø20mm + 1 x ø25mm + 4 x ø32mm 1 x ø20mm + 1 x ø25mm + 3 x ø32mm 2 x ø20mm + 1 x ø25mm


16 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm 19 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm 22 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm 36 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm 48 Modules 1 x ø32mm + 1 x ø40mm 1 x ø32mm + 1 x ø40mm


+ 4 x ø32mm + 1 x ø40mm 3 x ø20mm + 2 x ø25mm


+ 4 x ø32mm + 1 x ø40mm 3 x ø20mm + 3 x ø25mm


+ 4 x ø32mm + 1 x ø40mm 2 x ø20mm + 1 x ø25mm


+ 3 x ø32mm + 2 x ø40mm 3 x ø20mm + 3 x ø25mm


+ 3 x ø32mm + 2 x ø40mm


2 x ø20mm + 1 x ø25mm + 3 x ø32mm + 2 x ø40mm


3 x ø20mm + 2 x ø25mm + 3 x ø32mm + 2 x ø40mm


3 x ø20mm + 3 x ø25mm + 3 x ø32mm + 2 x ø40mm


2 x ø20mm + 1 x ø25mm + 3 x ø32mm + 2 x ø40mm


3 x ø20mm + 3 x ø25mm + 3 x ø32mm + 2 x ø40mm


• Positive contact status indication on Switch, MCB, RCD, RCBO & AFDD provided by green indicator to show contacts are open Product


Description


Consumer Units/Enclosures Plastic Enclosures/Enclosures Main Switch


RCD Type A 30mA RCD Type B 30mA MCB


RCBO Compact Type A 30mA RCBO Tall Type A 30mA


RCBO Compact Type A 30mA Bidirectional Double Pole


RCBO Compact Type F 30mA Bidirectional Double Pole


AFDD Tall 30mA Unidirectional SPD Type 2


Manufactured from 1.2mm steel and finished in powder coated high gloss finish paint, 100A Max load capacity Manufactured from ABS or Polycarbonate, available in IP20 or IP66, 100A Max load capacity 100A double pole, 2 module, for isolation of the incoming supply to the consumer Unit


40A, 63A, 80A & 100A double pole, 2 module, bidirectional RCD for isolation of supply and protection of earth leakage faults 63A double pole, 2 module, bidirectional RCD for isolation of supply and protection of earth leakage faults and specific for use on PV 6A - 55A single pole, 1module, bidirectional MCB B & C curve for general circuits with overload and short circuit protection 6A - 40A unidirectional, single pole, 1 module, RCBO B & C curve for general circuits with overload, short circuit and earth leakage protection 45A - 55A unidirectional, single pole, 1 module, RCBO B & C curve for general circuits with overload, short circuit and earth leakage protection


6A - 40A bidirectional double pole, 1 module, RCBO B & C curve for general circuits with overload, short circuit and earth leakage protection


16A - 40A bidirectional double pole, 2 module RCBO C curve for applications with variable speed drives and variable high frequencies occur with overload, short circuit and earth leakage protection


45A - 55A unidirectional, single pole, 1 module, AFDD for general circuits with overload, short circuit and earth leakage 40kA max discharge, 1 module, giving protection against transient overvoltages and protecting the electrical installation from damage


Contactors - Normally Open contacts 20A 1 module and 40A 2 module, 230V coil, for controlling lighting loads, heating or ventilation systems Bell Transformer Digital Timers Analogue timer


Time Delay Switch


2 module design, for use with mains powered door bells, steps down voltage from 240V AC to 8V AC 2 module design 230V with 1 or 2 channel application with 7 day function and manual overide function 3 module design 230V with single chanel operation application 24 hour function and manual overide function 1 module design 230V with 30 second to 20 minute count down period and manual overide function


Rear (mm)


1 x 100mm x 50mm 2 x 100mm x 50mm 2 x 100mm x 50mm 2 x 100mm x 50mm


4 x 100mm x 50mm 4 x 100mm x 50mm 6 x 100mm x 50mm 8 x 100mm x 50mm 12 x 100mm x 50mm


Max Torque Nm


2.5Nm 2Nm


2.5Nm L IN 2Nm


L/N out 1.2Nm 2Nm L


1.2Nm PE & N


L2 - 2Nm L1/N1 - 1.2Nm


• Devices – Pole Pitch 18mm


Consumer Unit 4 Modules 6 Modules 9 Modules 12 Modules 16 Modules 19 Modules 22 Modules 36 Modules 48 Modules


Width 172mm 208mm 262mm 316mm 388mm 442mm 494mm 387mm 495mm


Height 230mm 230mm 230mm 230mm 230mm 230mm 230mm 230mm 230mm


Depth 116mm 116mm 116mm 116mm 116mm 116mm 116mm 116mm 116mm


8


BG Circuit Protection


BG Circuit Protection


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28