GloQube Plus Specifications


®


Glow Discharge System for TEM Grids and Surface Modification


Note: The pump data is for the Pfeiffer DUO 6 Glow Discharge Processes Plasma current


HV power supply Maximum voltage Electrode polarity –


clean chamber Electrode polarity –


vapor chamber Sample stage


Pump hold time Process time


Safety Chamber vent inlets High voltage safety interlocks


Vacuum Vacuum control


Working vacuum range Vacuum isolation


Dimensions Instrument size


Instrument weight Pump*


Pump weight Footprint with pump


Communications Interface


Power requirements


Instrument power rating Pump power rating


Filtered air inlets with slow vent options to minimize sample disturbance


On-board reagent storage Reagents are contained in sealed glass vials to minimize exposure to hazards


Hardware safety interlocked and software for process control


Integrated pirani gauge 0.1 to 1 mbar


Pump min. requirements 5 m3 Pumping time


/hr, Inlet flange: KF 16.


Typical pump time to an operational vacuum of 0.1 mbar in 60 seconds


Isolation valves to switch vacuum and prevent process chamber cross-contamination


336 mm H x 364 mm D x 336 mm H 19.4 kg


391 mm W x 127 mm D x 177 mm H 16 kg


366 mm W x 600 mm D x 336 mm H USB 120 V 60 Hz, 15 A or 230 V 50 Hz, 10 A


100-240 V AC 60/50 Hz 700 VA including pump, IEC inlet 115/230 V 60/50 Hz 450 W


Ordering Information Cat No.


Description Qty.


GloQube Plus Dual chamber glow discharge system, Model #025235. Accessory kit, including: mains power lead, rotary pump power lead, oil mist filter and clamp, 750 mm long flexible stainless steel vacuum tube with clamps, fuses, glass vials, vial caps and sealing washers, needle (spare). Vacuum pump to be ordered separately.


Vacuum Pumping 91003


96001


/hr Pfeiffer DUO 6 two-stage rotary vacuum pump with oil mist filter


5 m3 each


Vacuum Pump Exhaust Filter including adapter (½" female NPT to ¾" BSPT with ¼" NPT plug)


Options, Accessories and Spares EMS-Glo-11 Microscope Slide Tray


EMS-Glo-12 Glass Vial


EMS-Glo-13 Glass Vial Caps EMS-Glo-14 Needle EMS-Glo-15 Door Seal


each each


10/pk 3/pk each each


Front Cover Micrographs: Top: Pseudomonas fluorescens Middle: Trematodes. Photo: Yann Quilichini (Microscopy Platform of the University of Corsica - Corte)


Bottom: Longitudinal Section of Mouse Skeletal Muscle - Nerve Cup (dense area myelin sheath). Photo: Nacer Benmeradi (R & D - DeltaMicroscopies-France)


Electron Microscopy Sciences P.O. Box 550 • 1560 Industry Rd. Hatfield, Pa 19440 Tel: (215) 412-8400 Fax: (215) 412-8450 email: info@emsdiasum.com or stacie@ems-secure.com


www.emsdiasum.com


1-50 mA 30 W 800 V


DC glow positive DC glow negative DC glow positive DC glow negative


125 x 100 mm (4.9" x 3.94") with location for two 25 x 75 mm (1" x 3") glass slides


Sample stage operational Adjustable 12.5 mm (0.5"), 22.5 mm (0.9") heights


or 35 mm (1.38") 0-72 hours