THE CRITICAL IMPORTANCE OF CORRECTLY SIZING AIR SOURCE HEAT PUMPS


Getting the size right is crucial for air source heat pump performance – too small or too large and effi ciency, comfort, and longevity suff er. Jamie Ansell of EDF Heat Pumps explains why detailed design matters.


THE FOUNDATION OF A CORRECTLY SIZED ASHP LIES IN A DETAILED HEAT LOSS CALCULATION


ir source heat pumps are an increasingly popular heating solution for new and existing homes, offering energy effi ciency, lower carbon emissions, and long-term cost savings. However, to realise their full potential, one key factor must be carefully addressed at the outset – correct sizing. An improperly sized heat pump can compromise both the performance and effi ciency of a system, leading to higher running costs, reduced comfort, and a shorter system lifespan.


A


When an ASHP is undersized for the property, it will struggle to meet the heating demands during colder weather. The unit may run continuously at maximum capacity, consuming more electricity than necessary and potentially failing to maintain a comfortable indoor temperature. This not only drives up energy bills but also increases mechanical wear, reducing the expected service life of the system.


On the other hand, an oversized heat pump can be just as problematic. ather than operating effi ciently, an oversized unit will frequently “cycle”


in spring and autumn switching on and off in quick succession as it rapidly overshoots the desired indoor temperature. Short cycling leads to unnecessary strain on system components, diminished effi ciency, and inconsistent indoor comfort. Poorly zoned central heating systems can make this scenario worse!


The foundation of a correctly sized ASHP lies in a detailed heat loss calculation. This process analyses factors such as insulation levels, window specifi cations, geographical location, air tightness, and overall fl oor area to determine the heating requirement of the property. Here at EDF heat pumps, we calculate each room’s heat loss giving us an overall heat loss fi gure for the building and from that we can determine the correct emitter sizes for each room. Relying on simple rules of thumb or oversimplifi ed estimates can lead to signifi cant errors  professional heat loss assessment ensures that the selected system is matched perfectly to the building’s needs, enabling the heat pump to operate at its optimal effi ciency range


Another important consideration for homeowners and installers is how to operate an air source heat pump effi ciently nlie traditional fossil fuel boilers that are typically run intermittently, ASHPs perform best when operated continuously. Running the system  at low fl ow temperatures allows it to maintain steady indoor conditions without the need for high energy inputs. This “low and slow” approach not only maximises system effi ciency but also enhances occupant comfort by eliminating signifi cant temperature fl uctuations throughout the day and night.


Correctly sizing and operating an air source heat pump is therefore essential to unlocking its full performance potential. For self-builders, renovators, and anyone upgrading their heating system, investing time in a proper design and specifi cation process will pay dividends in long-term comfort, energy savings, and system reliability.


Jamie Ansell is training manager at EDF Heat Pumps


WWW.HBDONLINE.CO.UK


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68