3.28 double-pole circuit breaker
device intended to interrupt both the neutral conductor (3.9) and active (phase) conductors (3.12) in a circuit simultaneously when a designated current is exceeded for a predetermined time
3.29 fuse
protective device that interrupts the circuit irreversibly when the current flow reaches a specified value for a specific time
[SOURCE: ISO 8820-1:2014, 3.2, modified – Note 1 to entry has been deleted.]
3.30 galvanic isolator
device which can be installed in series with the AC protective conductor (3.10) of the shore power cable to block low voltage DC galvanic current flow, but permits the passage of AC normally associated with the protective conductor
3.31 inverter
device powered by a DC source, designed primarily to provide AC power at a required voltage and frequency
3.32 inverter/charger
device designed to supply either AC power to a craft’s electrical system or to utilize the craft’s AC electrical distribution system to charge or maintain a battery or batteries supplying DC
3.33 extraneous conductive part
conductive part liable to introduce a potential, generally ground/earth potential, and not forming part of the electrical installation
3.34 ground plate
means to conduct the electrical current from a craft's conductive element to the water
3.35 craft small craft
recreational boat, and other watercraft using similar equipment, of up to 24 m length of hull (LH) Note 1 to entry: The measurement methodology for the length of hull is defined in ISO 8666. [SOURCE: ISO 8666:2020, 3.15, modified – Note 1 to entry has been added.]
4 General requirements, DC and AC systems 4.1 The hull of a metallic hull craft shall not be used as a circuit conductor.
4.2 Craft equipped with both DC and AC electrical systems shall have their distribution from either separate panel boards, or from a common one with a partition, or from other positive means to separate clearly the AC and DC sections from each other, and these shall be clearly identified.
4.3 Wiring diagrams to identify circuits, components and conductors shall be included with the craft. After completing an AC installation, it is recommended to perform a system test according to Annex C.
© ISO 2022 – All rights reserved 5
Distributed by the RYA under licence number 2020ET001 © BSI
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48