BS EN ISO 13297:2021+A11:2023 ISO 13297:2020+A1:2022
3.18 fully insulated two-wire DC system
system in which both positive and negative poles remain isolated from the ground (earth), e.g. not
connected to the water through a metallic hull, the propulsion system or earthed through the AC protective conductor (3.10)
Note 1 to entry: Some systems can use a momentary ground connection for engine starting purposes and can remain isolated.
3.19 self-limiting
device whose maximum output is restricted to a specified value by its magnetic or electrical characteristics
3.20 two-wire DC system with negative ground system in which the DC negative is connected to the ground
3.21 shore power appliance inlet
fitting designed for mounting on a craft, of a shrouded male type, to connect to the female connector on the craft end of the shore power cable in order to make the electrical connection for transmission of electrical energy
3.22 trip-free circuit breaker
mechanical switching device capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of overload or short circuit, and which is designed so that the resetting means cannot be manually held in place to override the current-interrupting mechanism
3.23 accessible
capable of being reached for inspection, removal or maintenance without removal of permanent craft structure
3.24 readily accessible
capable of being reached for use, inspection, removal or maintenance without the use of tools
3.25 sheath
uniform and continuous tubular protective covering of metallic or non-metallic material around one or more insulated conductors
Note 1 to entry: Examples of appropriate materials include moulded rubber, moulded plastic, woven sleeving or flexible tubing.
3.26 conduit
part of a closed wiring system of circular or non-circular cross-section for insulated conductors and/or cables in electrical installations, allowing them to be drawn in and/or replaced
3.27 cable trunking
system of closed enclosures comprising a base with a removable cover intended for the complete surrounding of insulated conductors, cables, cords and for the accommodation of other electrical equipment
4
© ISO 2022 – All rights reserved
Distributed by the RYA under licence number 2020ET001 © BSI
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48