8 GAS DETECTION How dangerous is a calibration gas cylinder?


Calibration gas cylinders are considered dangerous goods but how dangerous are they really? After all, most gas calibration gases are classified as “non-toxic, non-flammable” gases. Aside from the obvious hazards associated with flammable and toxic gases, all compressed gas cylinders have associated hazards which the user should be aware of.


It is important to understand the difference in UN DG classification and recognise dangers when using and handling cylinders. Even cylinders where contents are classified as non- toxic and non-flammable can be hazardous to health.


As noted in a previous article by CAC Gas, chlorine 2000ppm and below, in nitrogen, is considered non-toxic and non-flammable. As all occupational health and safety professionals know, concentrations of 2000ppm chlorine are very toxic (TWA: 1 ppm; STEL: 0.5ppm). Always read the SDS! Relying on the transport classification is not sufficient. Gases can vary greatly in danger, even if they are within the same UN classification.


Calibration gas cylinders can be pressurised between about 3 to 300 BAR. On the outside, a cylinder filled to 3 BAR will appear the same as one filled to 300 BAR. A cylinder filled to a higher fill pressure represents a greater danger if it is punctured, cracked or damaged.


It is unlikely for a cylinder to undergo explosive decompression without having suffered some sort of external damage. Certain cylinder types filled with certain components can be structurally compromised through chemical reactions over time. Refillable cylinders must undergo hydrostatic pressure testing every 10 years and non-refillable cylinders are single use only. Signs of such potential failures would be evident long before structural failures occurred.


Cylinders which undergo rapid or violent decompression can become missiles and cause significant damage. It is important not to underestimate the potential damage a venting cylinder can cause.


Secure your cylinders using mounts. Never leave cylinders where they can be bumped or knocked over. Avoid placing cylinders where there is potential for the valve to contact another object if it were to fall. Be careful when moving cylinders. When storing cylinders, ensure the protective valve cap is installed.


Rapid decompression can cause the cylinder to become extremely cold. Gases cool when they decompress, and temperatures can reach harmful levels if the decompression is violent enough. If the cylinder contacts skin, cold burns can result.


If you have a cylinder which is quickly decompressing do not attempt to touch the cylinder until sufficient time has passed to allow the cylinder to come back to ambient temperature. Some cylinders are upwards of 70Kg with a relatively small base to stand on. If a cylinder topples do not attempt to catch it or steady it as serious injury may occur.


Although it is not a good idea to leave your gas cylinders in direct sunlight, heat from sunlight alone will not cause your cylinder to explode. Calibration gas cylinders typically have working pressures at about half the burst pressure rating. To reach the burst pressure the cylinder would need to be exposed to extreme temperatures, such as in a fire.


Some cylinders are equipped with a pressure relief device. This device is designed to vent cylinder contents before the cylinder reaches burst pressure. It is conceivable that naturally occurring heat (such as strong sunlight on a hot day) could cause venting of cylinder contents.


More information online: ilmt.co/PL/YPV1 For More Info, email: email:


For More Info, email: email:


53708pr@reply-direct.com


GDS Supports Sustainable Hydrogen Technology


With a pedigree spanning over 30 years, GDS Technologies has a proud history of providing a diverse and bespoke range of gas detection solutions combined with market leading innovation. Built on an ethos of integrity and customer commitment, the company has remained at the forefront in the design and manufacture of products to suit an ever- changing market. The pace of in-house development and research continues unabated as GDS embraces the arrival of the Hydrogen revolution.


With countries increasingly committed to the use of renewable energy sources, Hydrogen as a clean and viable replacement for fossil fuels has the potential to score an instant win in the global race for net-zero emissions. Modern processes of splitting the molecular structure of water into Hydrogen (H2


) and Oxygen (O2


is now possible and is positioned to supersede even the most environmentally adept electric cells.


With water being the only direct emission, the so called ‘Hydrogen Highway’ is starting to see real traction in Hydrogen fuel cell batteries powering cars, buses, trains and even aircraft. This is a game changer for energy transition which could see the development of an annual €100 billion economy by 2025. As well as providing sustainable energy for electric vehicles, Hydrogen technology reduces carbon emissions in many industries and sectors, including utilities, industrial, battery charging, off peak excess power grid feed and much more.


GDS offer Hydrogen gas detection using proven, robust and reliable technology compatible with worldwide safe and hazardous area applications. A cost-effective compact package, the F6 Hydrogen gas detector conforms to international standards ATEX, IECEx.


• Explosion proof (Exd IIC) for high-risk gas / environments • 0~100% LEL range


• Addition of GDS Aspirator Sensor Units to eliminate working at heights (ASU-1/2) • Addressable or stand alone • Rugged and reliable • Highest standard of customer support


For more information contact our sales team sales@gds-technologies.co.uk or +44 (0)113 286 0166. More information online: ilmt.co/PL/wpoR


For More Info, email: email:


IET JANUARY / FEBRUARY 2021 WWW.ENVIROTECH-ONLINE.COM For More Info, email: 54204pr@reply-direct.com


) means a cleaner alternative to hydrogen production


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48