WATCH ESTING, , MING R, TOTA N &P & PRINTING CHTTESTINGTITIMIN,GO RATIOTIONRINTING


to sell Witschi products to the UK & Eire, for overseas customers we can offer the Greiner & TYMC alternatives.


• Simple testing system that can be used is workshop or retail environment


• Compact, sleek & elegant design • You have a choice of three colours and either “CLASSIC” or “SPORT” results display


• Connects to your computer via USB interface • Install the Witschi software on your PC, plug in the Chronocube and you are ready


Features: • Measures rate variation, amplitude and beat error in mechanical watches


• 5 measuring positions manually selectable (the measuring position is detected automatically and displayed on your computer screen)


• Automatic beat detection between 12,000 and 72,000 • The Chronocube consists of a measuring device and software, no parametrisation is necessary


• Choice of user interfaces: You have a choice of two user interfaces, “classic” and “sport”


• Three colours: The Chronocube is available in aluminium, steel and ruby


• Language selection: English, French, German, Spanish or Italian


Specification: • Rate precision: +/- 0.1s/d (range +/- 999s/d) • Amplitude precision: +/- 0.4 ° (range 80 ° to 360 °) • Beat error precision: +/- 0.1ms (range 0 to 9.9ms) • Vibration range: 12,000 to 72,000 • Lift angle: 10 ° to 90 ° (1 ° jumps) • Stabilization time: 20 seconds • Measure time: 1 hour maximum • Measuring positions: 5 • 110 x 110 x 115mm (width x height x depth) • 220 to 240 Volt (230 to 110 volt converter please see our code A52044)


Click website “More Information” & “PDF’s” for full specification.


For service, calibration & repairs of items inside and outside of the warranty period please submit a quote request via our online support under products & stock - product advice and repairs – Witschi equipment


calibration Code


W36034 W36032 W36033


Description


Aluminium Chronocube Red Chronocube Steel Chronocube


Witschi ChronoMaster UOM Price


EACH £1,215.00 EACH £1,215.00 EACH £1,215.00


overseas customers we can offer the Greiner & TYMC alternatives.


• Manual microphone with built in watch expert intelligence


• Shows your test results on your own computer or tablet


• No separate display screen, saving valuable space • Connects to your computer via USB interface • 4 programmable microphone buttons allows you to control the software


• Install the Witschi software on your PC, plug in the ChronoMaster and you have your own Witschi Watch Expert


2 different measurement methods are available to you for the quality control of mechanical watches with or without a strap. Rate accuracy, amplitude & beat error are all displayed numerically. The ChronoMaster Pro with its display on your PC works with operating systems; Windows 7, Windows 8.1 or Windows 10.


• Display modes: Continuous diamgram recording & vario display mode


• Automatic detection of 6 main positions, 4 vertical positions and 2 special positions


• Guided sequence mode, adjustable 1 to 10 testing positions


• Accurate positioning every 45 ° • Convenient operation of “Chronoscope Service” display software, thanks to built-in control buttons


• Automatic selection of all common beat numbers • Manual selection of any beat number between 3600 to 72,000


• Continuous diagram recording: selectable integration time 2 to 240s and adjustable zoom x1 to x16


• Secure mount, even for large watches • Works with your existing PC with windows on a computer or tablet


• Works with operating systems: Windows 7, Windows 8.1 or Windows 10


• Can work with the Omega co-axial escapement


Specification: • Beat error measurement range: 9.9ms • Rate precision: +/- 0.1s/d • Rate range: +/- 999.9s/d • Amplitude range: 70 ° to 360 ° (display possible to 999 °)


• Rate resolution: 0.1sd Code


W53342


Description ChronoMaster


UOM Price EACH


Witschi ChronoMaster Pro


• Shows your test results on your own computer or tablet


• No separate display screen, saving valuable space • Connects to your computer via USB interface • 4 programmable microphone buttons allows you to control the software


• Install the Witschi software on your PC, plug in the ChronoMaster Pro and you have your own Chronoscope S1 (with manual microphone)


6 different measurement methods are available to you for the quality control of mechanical watches with or without a strap. Rate accuracy, amplitude & beat error are all displayed numerically. The ChronoMaster Pro with its display on your PC works with operating systems; Windows 7, Windows 8.1 or Windows 10.


• Display modes: Continuous diamgram recording, vario display, trace display, sequence display, polar display & scope display


• Measures the rate accuracy, amplitude & beat error • Automatic detection of 6 main positions, 4 vertical positions and 2 special positions


• Guided sequence mode, adjustable 1 to 10 testing positions


• Accurate positioning every 45 ° • Automatic beat selection of all common beat numbers


• Manual selection of any beat number between 3600 to 72,000


• Continuous diagram recording: selectable integration time 2 to 240s and adjustable zoom x1 to x16


• Secure mount, even for large watches • Works with your existing PC with windows on a computer or tablet


• Works with operating systems: Windows 7, Windows 8.1 or Windows 10


• Can work with the Omega co-axial escapement


Specification: • Rate precision: +/- 0.1s/d (range +/- 999s/d) • Amplitude precision: +/- 1.0 ° (range 70 ° to 360 °) • Beat error precision: +/- 0.1ms (range 0 to 9.9ms) • Lift angle: 10 ° to 90 ° (0.1 ° jumps) • Stabilization time: 2 seconds to 60 minutes • Measure time: 2 seconds to 100 hours • Measuring positions: 10


Officially Appointed Witschi Distributor £1,595.00


Click website “More Information” & “PDF’s” for full specification.


For service, calibration & repairs of items inside and outside of the warranty period please submit a quote request via our online support under products & stock - product advice and repairs – Witschi equipment


calibration Code


W52038 Description ChronoMaster Pro UOM Price EACH £1,995.00 Witschi Chronoscope S1 (G2)


Witschi - ChronoMaster Pro - For Mechanical Movements


Witschi - ChronoMaster - For Mechanical Movements


Measuring rate variation, amplitude and beat errors in mechanical watches with 2 different display modes.


The Witschi ChronoMaster system is a stand alone testing system (a manual microphone with built in testing software) that offers the same testing specification as the watch expert, conducting & then displaying the results of professional mechanical watch tests on your existing PC or tablet screen.


• Witschi insist that UK distributors are only authorised to sell Witschi products to the UK & Eire, for


1166


The Witschi ChronoMaster Pro system is a stand alone testing system (a manual microphone with built in testing software) that offers the same testing specification as the Chronoscope S1, conducting & then displaying the results of professional mechanical watch tests on your existing PC or tablet screen.


• Witschi insist that UK distributors are only authorised to sell Witschi products to the UK & Eire, for overseas customers we can offer the Greiner & TYMC alternatives.


• Manual microphone with built in Chronoscope S1 intelligence


COUSINS TRADE SUPPLIER


Witschi - Chronoscope S1 (G2) - Generation 2 - With or without microphone - For Mechanical Movements


• Either supplied with standard microphone (T12040) or on its own


• Generation 2 Chronoscope S1 with capacitive touch screen


• Power range 100 to 240 volt (can be used either at 240 volt or 115 volt)


• Witschi insist that UK distributors are only authorised to sell Witschi products to the UK & Eire, for


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112