54 STRUCTURAL ELEMENTS


Fire Retardant Coatings our speciality


always at the forefront of exciting new technological advances. One such product recently developed by


I


the highly experienced research and development team is the new IRUFIRE B- s1,d0 fire retardant coating system based on two component Pu acrylic-aliphatic coatings. This system has been developed to coat


wooden surfaces which need to comply with the UNE-EN 13823: 2012 Standard of reaction to fire SBI (Single Burning Item) test and be classified according to UNE-EN 13501-2007 + A1:2010 (Euroclasses). The system comprises of a combination


of two main products, IRUFIRE PRIMER IP-1 and IRUFIRE TOPCOAT IT-1 which can be used to create coating systems that either maintain or upgrade to Euroclass B-s1,d0 classification.


rurena through dedicated research to develop the best wood coating, whatever the customer requirement, is


For use as a maintain system, for coating


walls and ceilings of wooden substrates that are flame retardant and are already certified as B-s1,d0 then only one coat of IRUFIRE PRIMER IP-1 at 80-100g/m² is required followed by one coat of IRUFIRE TOPCOAT IT-1 at the same film weight. The only variance for the upgrading coating system is the application of 2-3 coats of IRUFIRE PRIMER IP-1 is required to achieve a film weight of between 400-480g/m². In either system following application and


drying of the clear IRUFIRE PRIMER IP-1 it is lightly sanded with 240-320g abrasive and the sanding dust is removed prior to application of the chosen version of IRUFIRE TOPCOAT IT-1. The upgrade system has been tested on the


standard substrate as defined by EN13238: Reaction to fire tests for building products, conditioning procedures and general rules for selection of substrates. As such the B-s1,d0


classification obtained by this process can be extrapolated to any substrate of wood or wood derivative with a density equal or higher than 510kg/m³. The IRUFIRE B-s1,d0 system has been


certified for application in both clear coatings of any gloss level and pigmented coatings in any gloss level and any colour giving the user ultimate flexibility to ensure that the client requirements are able to be fulfilled. To further assist customers Movac has developed an easy to use calculator which works out the quantity of coating that is required of both the primer and topcoat based upon the area of square metres that require coating. For more information on these exciting technology products or for a copy of the IRUFIRE calculator contact Movac Group Ltd.


info@movac.com www.movac.com


WWW.ARCHITECTSDATAFILE.CO.UK


ADF DECEMBER 2019


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84