Feature
The Responsibility of Fire Safety in Healthcare
Fire safety is a major talking point in the industry right now. With the ongoing Grenfell Inquiry, concerns around fire safety are considerably high and rightly so. There is much confusion stemming from a distinct lack of clarity regarding exactly what the requirements are. What we’re seeing at Allegion are not
just issues pertaining to high-rise buildings, but across many different building types and industry sectors, in both public and government-owned buildings. Healthcare facilities, in particular, pose
incredibly complex safety challenges. Management teams must consider the facility’s occupants, the layout of the building, the purpose of each area, as well as carrying out regular maintenance checks and risk assessments and many other factors. A healthcare facility’s fire safety measures
will need to be both compliant with fire safety regulations and bespoke to the facility’s specific requirements. The regulations are complex, and navigating
a way through them to an effective fire safety plan can be difficult and painstaking. Here we provide some guidance on the key area of fire doors.
Fire Doors – do’s and don’ts
A number of regulations apply to both new and existing buildings in the UK, with the responsibility for fire risk assessment falling on the ‘responsible person.’ Fire doors play a major role in the fire
safety and protection of buildings. A damaged, faulty or misused fire door is one of the most common breaches of fire safety regulations. A propped open fire door, for example, is rendered obsolete. This is because in the
10 fmuk
event of a fire, they can only do their job if they can close. An open door will not prevent the spread of fire and smoke through a building to allow occupants to evacuate safety and protect the building. The most common type of fire door, FD30,
is appropriate in most cases. However, with fire doors, which are part of a compartment wall that separates buildings, a minimum of FD60 is required. Carrying out risk assessments should be
regular practice, as this ensures fire doors are kept in good working order.
The holistic view
A recent investigation into the Grenfell Tower fire dubbed the tower a “culture of non-compliance” on account for its lack of compliance with basic fire safety measures. Damaged or incorrectly fitted fire doors with gaps of up to 50mm between the door and frame, and missing door closers, meant the fire doors failed to perform. This means the fire failed to be compart- mentalized, and the spreading was undoubt- edly more severe than it should have been. On top of this, last year, fire chiefs warned
that 38 hospitals in the UK are as dangerous as the Grenfell Tower. As a result, more than 17,000 care homes, private hospitals and hospices were ordered to carry out imminent fire safety checks on their buildings. As an industry, it’s often easy to neglect one area of fire safety and prioritise another. For
Andrew Shaw An effective fire safety management and fire emergency plan requires both active and
passive fire precautions and a high degree of management. In healthcare facilities, an even higher degree of safety consideration is required since its occupants may need additional
assistance to escape in the event of a fire. Andrew Shaw, architectural consultant of Allegion UK, discusses ways to optimise fire safety in healthcare, and why a bespoke solution is key.
example, fixating on training or evacuation plans can force other areas such as the checking and maintenance of fire doors into second place. The holistic approach – that is, keeping on top of all areas equally – is key.
Bespoke over value engineering
With each facility being unique and diverse, it’s important to know which fire safety solutions and products are appropriate. Implementing suitable products is just
as important as the building’s fire safety management and training of staff. Because each facility will be different in terms of use and design, fire safety procedures must accommodate each diverse performance requirement. In considering this, it becomes easy to
make the mistake of prioritising cost over quality when this doesn’t have to be the case. Although, an effective fire safety strategy also doesn’t always mean cost-efficiency should be ruled out. Above all, understanding fire safety
requirements, possessing adequate fire safety solutions knowledge and carrying out appro- priate staff training requires minimal costs. Whilst many healthcare facilities, such
as hospitals, may be facing considerable budgetary pressures, requesting necessary assistance or expert guidance will help a facility meet fire safety standards and requirements based on its specific needs. This includes aesthetics and budget.
SOURCES
https://www.grenfelltowerinquiry.org.uk/
https://www.standard.co.uk/news/london/shock-grenfell-dossier-reveals-disastrous-refurbishment-turned-tower-into-a-tinderbox-a3814866.html https://www.telegraph.co.uk/news/2017/06/27/nhs-alert-fire-chiefs-warn-38-hospitals-dangerous-grenfell-tower/ http://www.bwfcertifire.org.uk/knowledge-centre/regulations http://www.bwfcertifire.org.uk/assets/bw638-build-regs-fc-1.pdf http://www.bwfcertifire.org.uk/assets/bw630-fire-safety-fc.pdf
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44