Getting compliance in basement projects
The UK continues to experience a boom in residential and commercial basement construction, with land in limited supply. Nik Ullfors of Visqueen looks at how to waterproof correctly to ensure compliance with the latest regulations
ny discussion of living in our cities invariably comes around to high house prices. This, coupled with the limited amount of land available for new builds and conventional extensions, has led to an explosion of new basement building with a 183 per cent increase in relevant planning applications since 2012 according to mortgage lender Halifax. So, while many are turning to basement developments as a solution to these pressures, it is important to recognise the challenges that expanding underground bring for both the architects designing these structures and the contractors building them.
A Getting it right
Unlike the regular walls of a house, which are in contact with water only sporadically, the walls of a basement can be in constant contact with groundwater, which leads to the danger of water ingress – causing damp, flooding and potential structural damage. Ensuring that a basement is therefore protected from groundwater is paramount. There can be severe financial
consequences for designers or builders who get this wrong with incorrectly installed waterproofing potentially leading to professionals being held liable. Between 2005 and 2013 the cost of these claims is estimated at £21m and has affected 890 homes. Added to this is the potential cost of expensive remedial works to rectify botched waterproofing damage and families having to leave their homes, while work takes place.
NHBC refers to this issue in its guidance
for basement waterproofing: “With this current boom in basements, and the frequency of below-ground waterproofing claims to registrations being circa 1600 times greater than foundation-related claims, below ground construction remains a cause of concern.”
ADF JULY 2018
The regulations – BS8102:2009 Basements must be designed and constructed to a minimum standard as defined in BS8102:2009 – the code of practice for the protection of below ground structures against water from the ground. The standard outlines the different approaches to waterproofing including the installation of external tanking with a waterproof membrane. Traditionally, it has been the role of architects to draw up and recommend the waterproofing design for below ground projects. However waterproofing design is a highly specialised area and the vast majority of architects will readily acknowledge that they do not have the detailed training or expertise to undertake this function. Often the only reason they have been doing it is because there are so few people in the industry who are willing to undertake this role! A lack of design expertise, combined with the need to provide effective overview of the installation on site can lead to
WWW.ARCHITECTSDATAFILE.CO.UK
49
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84