AM100 models are for hydronic heating applications. Straight thru design (hot & cold at same level). Lockable handwheel. Nickel plated brass/bronze construction.
AMX100 models are for domestic water applications. Designed to be installed directly on the water heater "Hot" discharge port. Integral check valve on cold water port. Bronze/stainless steel construction. Certified under ASSE1017, CSA & IAPMO approved.
AM100C models are for use with PEX systems for radiant heating. Straight thru design (hot & cold at same level). Lockable handwheel. Nickel plated brass/bronze construction.
MIXING VALVES - LEAD FREE CAT. NO. MFG. NO.
2K605LF AM100-US-1LF 1/2" Sweat - half Union 2K606LF AM101-US-1LF 3/4" Sweat - half Union 2K596LF AM101-1LF 2K607LF AM102-1LF
3/4" FPT 1" FPT
2K584LF AMX100-US-1LF 1/2" Sweat - half Union 2K585LF AMX101-US-1LF 3/4" Sweat - half Union 2K586LF AMX102-US-1LF 1" Sweat - half Union 2K597LF AM100C-1LF 2K594LF AM101C-1LF
1/2" FPT 3/4" FPT
CONNECTION SIZE/ TYPE MAX FLOW GPM TEMPERATURE RANGE EACH 8
12 12 20 6
14 20 8
12
MIXING VALVES Not For Use On Potable Water Applications
CAT. NO. MFG. NO. 2K588 2K589
AM101R-US-1 3/4" Sweat - half Union AM102R-US-1 1" Sweat - half Union
REPAIR KITS CAT. NO. MFG. NO. DESCRIPTION
4G7466 AM100-002RP Repair Kit for AM 100 Series Valves 2K590 2K592
AM-1-020RP Repair Kit for AM-100 Series Valves (C Range 80-125°F)
EACH $59.49 $67.34
AM-1-025RP Repair Kit for AM-100 Series Valves (STD Range 100-145°F) $67.34
CONNECTION SIZE/ TYPE MAX FLOW GPM TEMPERATURE RANGE EACH 12 20
The ARGO DPM2 monitors outside temperatures to adjust boiler water temperatures to match outdoor demand, maximizing efficiency and reducing fuel usage. Typical heating cost savings average 10-15% annually (depending on climate). The DPM2 reduces/increases boiler temperatures gradually reducing expansion/contraction noises in the home. Can be used in conjunction with any "ARM" series relay with supplied data port wiring harness, or as a stand alone control. DPM2 controller supplied with "ARM" relay compatibility cable, strap on supply water sensor, and outdoor sensor with shield.
CAT. NO. MFG. NO. POWER SUPPLY RELAY CAPACITY Sensor
5C915 DPM-2 20-28 VAC / 2 VA 24 VAC / 48 VA 1005 Ohms at 70° F* 0.5 - 1.5 * Accurate up to 500' with 18 gauge wire
RESET RATIO MAX. TEMP. DIFFERENTIAL EACH 150° - 210° 5° - 15°