FEATURE MACHINERY CENTRAL MACHINE MONITORING


Retrofitting production line machinery with an ‘open source’ mini computing system can extend lifetime, improves process efficiencies and result in cost savings, says HARTING


and can be fitted directly at the machine or on the DIN rail in the electrical cabinet. MICA is robust, has no fan and is maintenance-free. The system is designed for harsh industrial environments and resistant to dust, moisture and temperature fluctuations (IP67). Remote servicing for the MICA can be performed with a web browser. MICA has a modular design architecture


made from open hardware and software components. Unlike single-board computers such as the Raspberry Pi this device is divided into three control boards: a power and network, CPU and an end- user customisable function I/O. For this function board RFID, WLAN, BLE, SSD storage or fieldbus functionality can be integrated with suitable I/O connectivity, without changing the form factor or degree of protection of the MICA unit.


C


entral machine monitoring and process optimisation is the best way


to ensure that production lines and their associated constituent part machinery operate more effectively and economically. Many machines in well-established


production lines which may be 15-30 years old can still perform their main functional tasks successfully, however they do so much less efficiently than their modern day counterparts. For example, they don’t have the same level of computing power, sufficient memory capacity to record and store the relevant data or ability to communicate with modern equivalents. In many cases these machines use data formats and protocols from the 80s and 90s which are no longer used by today’s PLCs and industrial PCs.


EXAMPLE OF PLASTICS INJECTION MOULDING A prime example of a machine that might perform one critical function within a typical production line environment might be plastics injection moulding. Such machines when well-maintained can reach as much as a 30-year operational life. However, their main operating software protocol would almost certainly be no longer supported and virtualisation in the manufacturing execution system (MES) which is a control system for managing and monitoring work-in- process on a factory floor, would neither be economically sensible nor reliable. An MES keeps track of all manufacturing


2 MARCH 2017 | FACTORY EQUIPMENT 0


information in real time, receiving up-to- the-minute data from robots, machine monitors and employees. Although MES used to operate as self-contained systems they are increasingly being integrated with enterprise resource planning (ERP) software suites. Their goal is to improve productivity and reduce cycle-time, the total time to produce an order. HARTING’s MICA (modular industrial


computing architecture) edge computing device can directly address these issues, upgrading older machines by providing a protocol converting gateway to the central operating software controls of the newer version at a fraction of the investment cost of such a new machine. This is due to the fact that with MICA’s


modular open platform, the HARTING IIC MICA permits the user to choose the programming language and development environment according to what they are more familiar with. It can create a virtual image of a device or a machine in the digital world and enables modern interfaces for devices whose communications are outdated.


CONVERT OLD MACHINE PROTOCOLS This means that you can convert old machine protocols into OPC-UA or MQTT (a machine-to-machine (M2M)/IoT connectivity protocol) in order to connect legacy machines to IoT or MES systems MICA fits anywhere: with dimensions of 13 x 8 x 3.5 cm it is extremely compact


Old machine protocols can be converted into OPC-UA or MQTT in order to connect legacy machines to IoT or MES


OPEN SYSTEM SOFTWARE ENVIRONMENT MICA is easy to use with the touch- optimised interface for end users and administrators implemented entirely in HTML5 and JavaScript. It provides an open system software environment that allows developers from both the production and IT worlds to quickly implement projects and customise without special tools. Applications are executed in their own


Linux-based containers which contain all the necessary libraries and drivers. This means that package dependencies


and incompatibilities are a thing of the past.


In addition, such containers run in


individual ‘sandboxes’ which isolate and secure different applications from each other with their own separate log-in and IP address. As a result, there should be no concerns over data security when MICA is allowed access to a higher-level production operating network. MICA is already offered with containers


including Java, Python C/C++, OPC-UA, databases and web toolkits. The modularity and use of an intermediate JSON format allow other legacy systems to be integrated in the future with minimal effort; only the log-input container is replaced. Additional protocols can be easily supported by replacement of a container on the server side eg MQTT.


Harting T: 01604 827500 salesUK@HARTING.com www.HARTING.co.uk/mic





Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57