® Safety Showers & Eyewash products 1250ltr TANK SHOWER


SE-VTS-2 The emergency shower solution for when a constant water supply or adequate water pressure is unavailable. This model requires a pump to comply with ANSI Z358.1 flow rates. Supported on a 40mm x 40mm x 3mm hot dip galvanised (provides corrosion protection) carbon steel, square tubular frame with bolt down fixing brackets, the moulded polyethylene 2000ltr water tank is covered in 40mm reflective Kingspan Thermapitch® TP10 rigid polyurethane foam, insulation board (0.022W/m.k thermal conductivity) and the tank structure is further protected by a shroud complete with warning signage. The heating element sits in a sump to ensure it is covered at all times, even if the tank is completely empty and the system is fitted with a test activation handle which is accessed from outside the shower area.


CODE SE-VTS-2


DESCRIPTION


1250ltr tank shower - 1320mm x 1430mm x 3600mm H (overall height) - un-laden weight 470kg - filled weight 1775kg heating 2.25” BSP connection with 230v 3kw rated, wired to a rotary isolation switch - water temperature maintained at approximately 30°C in an ambient of ¯10°C including wind chill - Needs to be fitted with an optional electric pump to ensure compliance with the ANSI Z358.1 flow standard of 75.7lpm over 15 minutes duration - full stainless steel construction shower head - all wetted parts are manufactured from non-ferrous materials - activation of shower is via a full width bar across the rear of the unit which also extends beyond the framework for remote & test activation - basic water level indicator fitted to main tank structure


ANSI TIP Safety showers and/or eyewash stations must be located on the same level as the hazard and the pathway between them must be clear of obstructions. If your facility contains a hazardous area that is located on a different level to your current emergency flushing area, you will have to install further equipment on the same level as the hazard.


www.empteezy.co.uk


5


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36