This page contains a Flash digital edition of a book.
Diagram 7 TPS-77 Pd Calculation 43. 44.


In the absence of actual data, the calculated data will be used to determine the Pd of a turbine at the limits of LoS.


For Pd calculations, turbines were simulated along the northern edge of the East Anglia THREE site at the locations correlating with LoS contours as shown at Diagram 8.


MOD Trimingham Radar Simulated Turbines


East Anglia THREE Boundary


Diagram 8 Trimingham Radar Pd Simulations 45.


The 6 simulated turbines are 195m, 204m, 220m, 244m, 260m, and 280m tip heights as viewed from left to right. As explained in Section 16.5.1 above, turbines with a tip


Preliminary Environmental Information May 2014


East Anglia THREE Offshore Windfarm


Appendix 0 Example Page 11


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29